Potter INS-250 Wall Mountable Nitrogen Generator

File Preview
File Preview
Click below to download for free

File Data

Name potter-ins-250-wall-mountable-nitrogen-generator-3758064291.pdf
Type PDF
Size 1.22 MB
Downloads

Text Preview

Features potter Intelligen Controller patent pending Fully automates the air fill and nitrogen fill procedure Advance leak rate detection Integrated Bypass alarm Web Enabled system can be monitored anywhere there is connectivity Automatically e mails trouble alerts and maintenance Integrated 1 2 HP oil less air compressor included to meet NFPA required 30 minutes fill for 300 gallon system at 40 PSI Handles up to 1,000 gallons of total sprinkler system capacity Easy plug and play installation 10 gallon nitrogen tank Form C dry contacts for Building Management System BMS Intelligen Series of Nitrogen Generators are specifically to generate on site 98 purity nitrogen for use in fire sprinkler systems When used as a supervisory gas in fire systems nitrogen slows corrosion improves the life of your and lowers maintenance costs INS 250 utilizes nitrogen membrane technology for gas Nitrogen membranes are highly effective and a cost way of producing on site nitrogen Acting as a gas filter the membrane separates the oxygen and water vapor molecules the air from the nitrogen molecules The high purity nitrogen gas then piped through the air maintenance device and into the fire system As the system fills with nitrogen the remaining molecules in the fire protection system are exhausted by using Potter IntelliPurge Nitrogen Purge Valve The Potter IntelliPurge Purge Valve monitors the fire protection system to ensure purity nitrogen is consistent throughout the sprinkler system INS 250 is a fully assembled package ready to be connected to a or existing fire sprinkler system This turn key system includes an air compressor nitrogen membrane tank all air filtration and the Potter IntelliGen Controller Potter IntelliGen Controller ensures the contractor the easiest and operation of any nitrogen generator system in the industry unit is designed to be turned on and walk away The built in capabilities will make corrections and alert you to any changes Specifications H X 26 W X 12 D H X 18 W X 10 lbs 5.7A single phase 230 240V 2.8A single Cabinet Size Tank Size Supply Available in Sprinkler System Cabinet Mounting Holes Tank Mounting pressure Range Female NPT 5 16 1 2 PSI 10 to 110 43 Potter INS 250 should be installed in a dry clean and well room with ambient temperatures above 50 at all times access to the front for service and place the unit in a location that conveniently located near fire sprinkler system connections a drain a dedicated electrical connection The Potter IntelliGen Nitrogen should always be installed in an adequately ventilated room release of nitrogen gas into an enclosed space displaces the and can cause an asphyxiation hazard For detailed installation operation instructions please refer to the Potter IntelliGen Generator Manual 5403644 page 1 OF 3 Nitrogen Generator8820037 REV A 02 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Dimensions 1 KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION 1 4 1 4 1 4 1 4 1 4 1 4 24 1 2 24 1 2 24 1 2 24 1 2 24 1 2 24 1 2 1 4 1 4 1 4 1 4 1 4 1 4 1 2 1 2 1 2 1 2 1 2 1 2 MOUNTING HOLES 4 PLCS MOUNTING HOLES 4 PLCS MOUNTING HOLES 4 PLCS MOUNTING HOLES 4 PLCS MOUNTING HOLES 4 PLCS MOUNTING HOLES 4 PLCS MOUNT BRACKET TO STUDS USING BOLT 4 PLCS MOUNT BRACKET TO STUDS USING BOLT 4 PLCS DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY COMPRESSOR ON OFF SWITCH COMPRESSOR ON OFF SWITCH ELECTRICAL CONDUIT CONNECTION PLCS COMPRESSOR ON OFF SWITCH COMPRESSOR ON OFF SWITCH ELECTRICAL CONDUIT CONNECTION PLCS COMPRESSOR ON OFF SWITCH COMPRESSOR ON OFF SWITCH ELECTRICAL CONDUIT CONNECTION ELECTRICAL CONDUIT CONNECTION PLCS PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION ELECTRICAL CONDUIT CONNECTION PLCS PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS FNPT NITROGEN OUT A FNPT NITROGEN OUT A FNPT NITROGEN OUT A FNPT NITROGEN OUT A FNPT NITROGEN OUT A FNPT NITROGEN OUT A CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS CONNECTION CONNECTION TO FLOOR DRAIN USING PROVIDED TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE OD X 10 PUSH TO CONNECT TUBE PLCS PLCS CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS PAGE 2 OF 3 REV A 02 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comINS 250IntelliGen Nitrogen Generatorfirealarmresources com Dimensions 2 FNPT BALL VALVE INLET A 1 2 PLCS SAFETY RELIEF VALVE TANK PRESSURE GAUGE FNPT BALL VALVE SYSTEM CONNECTION 1 2 GALLON NITROGEN TANK X 7 8 SLOT 90 A PLCS APART BOLT CIRCLE FNPT BALL VALVE Information Number 115 120VAC 1PH 60 HZ 230 240VAC 1PH 60 HZ Nitrogen System 250 115 120VAC Single Phase Nitrogen System 250 230 240VAC Single Phase Nitrogen Purge Valve Purge Valve Air Maintenance Device Nitrogen Analyzer page 3 OF 3 REV A 02 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comINS 250IntelliGen Nitrogen Generatorfirealarmresources com

Related Files