Potter INS-600 Wall Mountable Nitrogen Generator
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-ins-600-wall-mountable-nitrogen-generator-2784165390.pdf |
---|---|
Type | |
Size | 1.26 MB |
Downloads |
Text Preview
Features potter Intelligen Controller patent pending Fully automates the air fill and nitrogen fill procedure Advance leak rate detection Integrated Bypass alarm Web Enabled system can be monitored anywhere there is connectivity Automatically e mails trouble alerts and maintenance Two Integrated 1 2 HP oil less air compressors included to meet 13 required 30 minutes fill for 525 gallon system at 40 PSI Handles up to 2,350 gallons of total sprinkler system capacity Easy plug and play installation 20 gallon nitrogen tank Form C dry contacts for Building Management System BMS Intelligen Series of Nitrogen Generators are specifically to generate on site 98 purity nitrogen for use in fire sprinkler systems When used as a supervisory gas in fire systems nitrogen slows corrosion improves the life of your and lowers maintenance costs INS 600 utilizes nitrogen membrane technology for gas Nitrogen membranes are highly effective and a cost way of producing on site nitrogen Acting as a gas filter the membrane separates the oxygen and water vapor molecules the air from the nitrogen molecules The high purity nitrogen gas then piped through the air maintenance device and into the fire system As the system fills with nitrogen the remaining molecules in the fire protection system are exhausted by using Potter IntelliPurge Nitrogen Purge Valve The Potter IntelliPurge Purge Valve monitors the fire protection system to ensure purity nitrogen is consistent throughout the sprinkler system INS 600 is a fully assembled package ready to be connected to a or existing fire sprinkler system This turn key system includes an air compressor nitrogen membrane tank all air filtration and the Potter IntelliGen Controller Potter IntelliGen Controller ensures the contractor the easiest and operation of any nitrogen generator system in the industry unit is designed to be turned on and walk away The built in capabilities will make corrections and alert you to any changes Specifications Cabinet Size Tank Size Supply Available in Sprinkler System Cabinet Mounting Holes Tank Mounting pressure Range H X 27.5 W X 12 D H X 18 W X 10 lbs 11.4A single phase 230 240V 5.6A phase 60 Hz Female NPT 5 16 3 8 PSI 10 to 110 43 Potter INS 600 should be installed in a dry clean and well room with ambient temperatures above 50 at all times access to the front for service and place the unit in a location that conveniently located near fire sprinkler system connections a drain a dedicated electrical connection The Potter IntelliGen Nitrogen should always be installed in an adequately ventilated room release of nitrogen gas into an enclosed space displaces the and can cause an asphyxiation hazard For detailed installation operation instructions please refer to the Potter IntelliGen Generator Manual 5403725 page 1 OF 3 Nitrogen Generator8820100 REV B 10 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com KNOCKOUT FOR BMS AND NETWORK CONNECTION Dimensions 1 KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION KNOCKOUT FOR BMS AND NETWORK CONNECTION 46 1 4 46 1 4 46 1 4 46 1 4 DISPLAY COMPRESSOR ON OFF SWITCH ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS 34 1 2 DISPLAY DISPLAY DISPLAY COMPRESSOR ON OFF SWITCH COMPRESSOR ON OFF SWITCH COMPRESSOR ON OFF SWITCH ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS 30 3 4 27 3 4 NPT NITROGEN OUT 14 1 4 MOUNT BRACKET TO STUDS USING BOLT 4PLCS 30 3 4 27 3 4 2 3 4 MOUNTING HOLES 4 PLCS 30 3 4 27 3 4 30 3 4 27 3 4 NPT NITROGEN OUT DISPLAY COMPRESSOR ON OFF SWITCH ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS DISPLAY 2 3 4 MOUNTING HOLES 4 PLCS COMPRESSOR ON OFF SWITCH 14 1 4 ELECTRICAL CONDUIT CONNECTION PLCS ELECTRICAL CONDUIT CONNECTION PLCS 2 3 4 2 3 4 NPT NITROGEN OUT MOUNTING HOLES 4 PLCS MOUNTING HOLES 4 PLCS NPT NITROGEN OUT NPT NITROGEN OUT MOUNT BRACKET TO STUDS USING BOLT 4 PLCS 14 1 4 14 1 4 CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS NPT NITROGEN OUT CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PLCS CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE CONNECTION TO FLOOR DRAIN USING PROVIDED OD X 10 PUSH TO CONNECT TUBE PAGE 2 OF 3 REV B 10 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comINS 600IntelliGen Nitrogen Generatorfirealarmresources com Dimensions 2 35 3 4 35 3 4 35 3 4 23 1 2 23 1 2 19 3 4 23 1 2 19 3 4 19 3 4 19 1 2 19 1 2 19 1 2 11 3 4 11 3 4 11 3 4 TANK PRESSURE GAUGE TANK PRESSURE GAUGE TANK PRESSURE GAUGE SAFETY RELIEF VALVE SAFETY RELIEF VALVE SAFETY RELIEF VALVE GALLON NITROGEN TANK GALLON NITROGEN TANK GALLON NITROGEN TANK X 3 4 SLOT PLCS Information Number X 3 4 SLOT PLCS X 3 4 SLOT PLCS 115 120VAC 1PH 60 HZ 230 240VAC 1PH 60 HZ BALL VALVE MUFFLER BALL VALVE MUFFLER BALL VALVE MUFFLER Nitrogen System 600 115 120VAC Single Phase Nitrogen System 600 230 240VAC Single Phase Nitrogen Purge Valve Purge Valve Air Maintenance Device Nitrogen Analyzer page 3 OF 3 REV B 10 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comINS 600IntelliGen Nitrogen Generatorfirealarmresources com