Potter Installation Manual LED-16F LED Annunciator Flush Mount

File Preview
File Preview
Click below to download for free

Text Preview

Installation Manual LED 16F LED Annunciator Flush Mount TO THE INSTALLER manual provides an overview and the installation instructions for the LED 16F module terminals are power limited and should be wired in accordance with the requirements of NFPA 70 NEC and NFPA 72 National Alarm Code Failure to follow the wiring diagrams in the following pages will cause the system to not operate as intended For information refer to the control panel installation instructions module shall only be installed with listed control panels Refer to the control panel installation manual for proper system Description LED 16F is a LED remote annunciator LED 16F communicates using a RS 485 connection to the main panel providing zone indication of Alarm Supervisory and Trouble conditions The module mounts on either a 4 square or double gang box LED 16F features 2 slide in labels allowing each of the 16 zones to be customized for any application It can be mounted on single gang electrical box or a four square electrical box The annunciator utilizes a sheet metal enclosure secured with a Potter Setting the Address LED 16F address is set by dip switch S1 which is located on the back of the LED 16F The address must be set in the range one to thirty one 1 to be recognized by the panel 1 Example of Setting Address on the LED 16F panel view Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406319 A 02 16 PAGE 1 OF 3 P Link device has a five 5 position dip switch which is used to program the device address ranging from one 1 to thirty 31 The table below may be used to set dip switches when addressing any P Link module 2 Dip Switch Settings Table Addresses 1 16 16 16 16 Each gray box indicates that the dip switch is On and each white box indicates Off examples shown below illustrate a P Link dip switch settings the 1st example shows a P Link module not addressed where dip switch settings are in the default Off position the 2nd illustrates an addressed P Link module via the dip switch settings 3 Examples of P Link Module Showing Default Dip Switch Setting Unaddressed Addressed 4 4 dip switches are in the Off shows this P Link module 10 Dip switches 2 8 in the On position connecting a device to the RS 485 take the following precautions to prevent potential damage to the RS 485 connection or or device Technical Specifications to the LED 16F is removed wiring on module is correctly installed wiring has no open or short circuits Current 24 VDC Current 24 VDC Temperature Range Humidity Range Wire Length no of PAD100 LEDFs Mount Size WxHxD Mount Size WxHxD PWR Maximum Standby Current VDC 33 VDC PWR Maximum Alarm Current VDC 33 VDC mA mA to 120 F 0 to 49 C non condensing ft 3 8 x 9 1 4 x 7 8 3 8 x 9 1 4 x 3 1 8 mA mA Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406319 A 02 16 PAGE 2 OF 3 MANUAL LED 16F LED ANNUNCIATOR FLUSH MOUNTfirealarmresources com Installation LED 16F is connected to the fire alarm control panel using a four wire RS 485 connection The connection is power limited supervised Up to 31 LED 16F LED annunciators can be connected Refer to the illustrations below for a front panel and board 4 LED 16F Module Showing Front Panel Board are inserted here needed labels be here Wiring Diagram following wiring diagrams illustrate how to wire a LED 16F to Control Panel or Auxiliary Power 5 Wiring LED 16F to Control Panel or Auxiliary Power Example 608 4 608 5 by panel by supply PWR P Link A B PWR P Link A B PWR can be provided by any fire listed source LED power must be 16 VDC 33 VDC and must be power limited from panel from from panel RS 485 supports the Class A and Class B RS 485 connection is power limited and supervised Wire Preparation Strip all wires 1 4 inch from their edges as shown here wiring is between 12 max and 22 min Stripping too much insulation may cause a ground fault Stripping too little may cause a poor connection and subsequently an open circuit inch instructions do not purport to cover all the details or variations in the equipment described nor provide for possible contingency to be met in connection with installation operation and maintenance subject to change without prior notification Technical Assistance contact Potter Electric Signal Company at 866 956 1211 performance is based on proper application of the product by a qualified professional further information be desired or should particular problems arise which are not covered sufficiently for purchaser purpose the matter should be referred to a distributor in your region Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406319 A 02 16 PAGE 3 OF 3 INSTALLATION MANUAL LED 16F LED ANNUNCIATOR FLUSH MOUNTfirealarmresources com

Related Files