Potter Installation Manual PAD100-DRTS Duct Remote Test Switch
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-installation-manual-pad100-drts-duct-remote-test-switch-7290364518.pdf |
---|---|
Type | |
Size | 806.75 KB |
Downloads |
Text Preview
Installation Manual PAD100 DRTS Duct Remote Test Switch TO THE INSTALLER manual provides an overview and the installation instructions for the PAD100 DRTS module This module is only compatible addressable fire systems that utilize the PAD Addressable Protocol terminals are power limited and should be wired in accordance with the requirements of NFPA 70 NEC and NFPA 72 National Alarm Code Failure to follow the wiring diagrams in the following pages will cause the system to not operate as intended For information refer to the control panel installation instructions module shall only be installed with listed control panels Refer to the control panel installation manual for proper system Description PAD100 DRTS provides a supervised remote test switch for the PAD100 DUCTR duct detector Active and Pilot LEDs provide of the PAD100 DUCTR detector Keyed switch allows remote testing of the PAD100 DUCTR duct detector It installs on a gang box or Potter P32 BB DBB connecting a device to the PAD100 DUCTR take the following precautions to prevent potential damage to the SLC or Technical Specifications to the PAD100 DUCTR is removed wiring on module is correctly installed wiring has no open or short circuits mA mA Voltage Standby Current Alarm Current no of PAD100 DRTS per PAD100 DUCTR 1 Temperature Range Humidity Range Options Weight to 120 F 0 to 49 C Indoor Only to 93 non condensing L x 2.75 W x 1 D gang box or Potter P32 BB DBB lbs Wiring Diagram wiring diagram shown below illustrates how to wire a PAD100 DRTS Additionally an installation diagram shows how to install module using a compatible electrical box 1 Example of Installing a PAD100 DRTS Using a Compatible Electrical Box Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406313 A 02 16 PAGE 1 OF 2 2 Example of Wiring a PAD100 DRTS Duct Detector ADDRESSABLE DETECTOR Wire Preparation Strip all wires 1 4 inch from their edges as shown here wiring is supervised wiring is between 12 max and 22 min Stripping too much insulation may cause a ground fault Stripping too little may cause a poor connection and subsequently an open circuit inch instructions do not purport to cover all the details or variations in the equipment described nor provide for possible contingency to be met in connection with installation operation and maintenance subject to change without prior notification Technical Assistance contact Potter Electric Signal Company at 866 956 1211 performance is based on proper application of the product by a qualified professional further information be desired or should particular problems arise which are not covered sufficiently for purchaser purpose the matter should be referred to a distributor in your region Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406313 A 02 16 PAGE 2 OF 2 MANUAL PAD100 DRTS DUCT REMOTE TEST SWITCHfirealarmresources com