Potter Installation Manual PAD100-IM Isolator Module

File Preview
File Preview
Click below to download for free

File Data

Name potter-installation-manual-pad100-im-isolator-module-7930248615.pdf
Type PDF
Size 969.74 KB
Downloads

Text Preview

Installation Manual PAD100 IM Isolator Module TO THE INSTALLER manual provides an overview and the installation instructions for the PAD100 IM module This module is only compatible with fire systems that utilize the PAD Addressable Protocol terminals are power limited and should be wired in accordance with the requirements of NFPA 70 NEC and NFPA 72 National Alarm Code Failure to follow the wiring diagrams in the following pages will cause the system to not operate as intended For information refer to the control panel installation instructions module shall only be installed with listed control panels Refer to the control panel installation manual for proper system Description PAD100 IM does not require an SLC loop address but does consume power the from the SLC loop The module provides against short circuits by limiting the number of affected devices When the PAD100 IM detects a short circuit on the loop it disconnects the outgoing side of the module to prevent the short from affecting the rest of the SLC loop The module on either an UL Listed 2 1 2 deep 2 gang box or 1 1 2 deep 4 square box PAD100 IM includes one red LED to indicate the module status When the module is shorted the LED will light continuously the short is removed the PAD100 IM will automatically restore to a cleared condition connecting a device to the SLC loop take the following precautions to prevent potential damage to the SLC or device Technical Specifications to the SLC is removed wiring on module is correctly installed wiring has no open or short circuits Voltage SLC Standby Current SLC Short Circuit Current no of PAD100 IM on SLC Loop Temperature Range Humidity Range Options Weight A Units to 120 F 0 to 49 C to 93 non condensing L x 4.17 W x 1.14 D Listed 2 1 2 deep 2 gang box or deep 4 square box lbs Wiring Diagrams wiring diagram shown below illustrates how to wire a PAD100 IM module as Class X Additionally an installation diagram how to install the module using a compatible electrical box 1 Example of Installing a PAD100 IM Using a Compatible Electrical Box Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406310 A 02 16 PAGE 1 OF 2 2 Example of Wiring a PAD100 IM as Class X FACP OR MODULE FACP OR NEXT Wiring style supports the Class A Class X and Class B Wiring for terminals IN1 IN2 IN3 are supervised Wiring for terminals IN1 IN2 IN3 are power limited Wire Preparation Strip all wires 1 4 inch from their edges as shown here wiring is between 12 max and 22 min Stripping too much insulation may cause a ground fault Stripping too little may cause a poor connection and subsequently an open circuit inch instructions do not purport to cover all the details or variations in the equipment described nor provide for possible contingency to be met in connection with installation operation and maintenance subject to change without prior notification Technical Assistance contact Potter Electric Signal Company at 866 956 1211 performance is based on proper application of the product by a qualified professional further information be desired or should particular problems arise which are not covered sufficiently for purchaser purpose the matter should be referred to a distributor in your region Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406310 A 02 16 PAGE 2 OF 2 MANUAL PAD100 IM ISOLATOR MODULEfirealarmresources com

Related Files