Potter Installation Manual PAD100-NAC NAC Module

File Preview
File Preview
Click below to download for free

File Data

Name potter-installation-manual-pad100-nac-nac-module-8041956327.pdf
Type PDF
Size 1.13 MB
Downloads

Text Preview

Installation Manual PAD100 NAC NAC Module TO THE INSTALLER manual provides an overview and the installation instructions for the PAD100 NAC module This module is only compatible addressable fire systems that utilize the PAD Addressable Protocol terminals are power limited and should be wired in accordance with the requirements of NFPA 70 NEC and NFPA 72 National Alarm Code Failure to follow the wiring diagrams in the following pages will cause the system to not operate as intended For information refer to the control panel installation instructions module shall only be installed with listed control panels Refer to the control panel installation manual for proper system Description PAD100 NAC module uses one 1 SLC loop address on an SLC loop The module provides a programmable source of power supervise and control one 1 Class B or Class A Notification or one 1 Class B Releasing circuit The module requires and a 24 VDC auxiliary power connection The module mounts on either an UL Listed 2 1 2 deep 2 gang box or 1 1 2 4 square box PAD100 NAC includes one red LED to indicate the module status In normal condition the LED flashes when the device is polled by the control panel If the LED blink has been disabled via the programming software in a normal condition the LED the device will be off Setting the Address PAD protocol detectors and modules require an address prior to connection to the panel SLC loop Each PAD device i e detector and or module is set by changing the dip switches located on the device PAD device addresses are of a seven 7 position dip switch used to program each device with an address ranging from 1 1 PAD Device Dip Switch Addresses Table Addresses 1 16 32 64 16 32 64 16 32 64 16 32 64 16 32 64 16 32 64 Each gray box indicates that the dip switch is On and each white box indicates Off 16 32 64 16 32 64 16 32 64 16 32 64 examples shown below illustrate a PAD device dip switch settings the 1st example shows a device not addressed where all switch settings are in the default Off position the 2nd illustrates an addressed PAD device via the dip switch settings 2 Examples of PAD Device Showing Default Dip Switch Setting Unaddressed Addressed PAD Device 4 64 4 64 dip switches are in the Off shows this PAD device 42 Dip switches 2 8 are in the On position Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406309 A 02 16 PAGE 1 OF 3 to the SLC is removed wiring on module is correctly installed wiring has no open or short circuits connecting a device to the SLC loop take the following precautions to prevent potential damage to the SLC or device Technical Specifications Voltage SLC Standby Current SLC Alarm Current Power Required Ratings Resistor Resistor Diode Temperature Range Humidity Range no of PAD100 NAC Options A A VDC VDC 2A 3005012 Releasing Applications Not Included to 120 F 0 to 49 C to 93 non condensing units L x 4.17 W x 1.14 D Listed 2 1 2 deep 2 gang box or deep 4 square box lbs Weight Installation wiring diagrams shown below illustrate how to wire a PAD100 NAC module as Class B Class A and as a Releasing Additionally an installation diagram shows how to install the module using a compatible electrical box 3 Example of Installing a PAD100 NAC Using a Compatible Electrical Box 4 Example of Wiring a PAD100 NAC as Class B FACP OR MODULE NEXT MODULE 24 POWER FACP W CLASS B RESISTOR OHM 3005013 SUITABLE FOR OF Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406309 A 02 16 PAGE 2 OF 3 INSTALLATION MANUAL PAD100 NAC NAC MODULEfirealarmresources com CLASS A END OF LINE IS NOT SUITABLE FOR OF APPLIANCES 5 Example of Wiring a PAD100 NAC as Class A FACP OR MODULE NEXT MODULE VOLT POWER FROM FACP PREVIOUS MODULE VOLT POWER TO FACP NEXT MODULE FACP OR MODULE NEXT MODULE VOLT POWER FACP 6 Example of Wiring a PAD100 NAC as a Releasing Application Releasing Solenoid END OF LINE DIODE REQUIRED 305012 EOL DEVICE SHALL BE INSTALLED IN SAME ELCTRICAL ENCLOSURE AS THE DEVICE wiring style supports the Class A Class X and Class B NAC wiring style supports Class A and Class B Wiring for terminals PWR are supervised Wiring for terminals SLC SLC are supervised Wiring for terminals RET OUT are supervised wiring is between 12 max and 22 min Wire Preparation Strip all wires 1 4 inch from their edges as shown here loop wiring SLC SLC and NAC device wiring RET OUT are power limited Stripping too much insulation may cause a ground fault Stripping too little may cause a poor connection and subsequently an open circuit inch is possible that the internal relay in the PAD100 NAC may be shipped in the non normal activated state To that the internal relay is set to the normal state connect the module to the SLC loop and reset the control before terminating the wiring to the module output instructions do not purport to cover all the details or variations in the equipment described nor provide for possible contingency to be met in connection with installation operation and maintenance subject to change without prior notification Technical Assistance contact Potter Electric Signal Company at 866 956 1211 performance is based on proper application of the product by a qualified professional further information be desired or should particular problems arise which are not covered sufficiently for purchaser purpose the matter should be referred to a distributor in your region Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406309 A 02 16 PAGE 3 OF 3 INSTALLATION MANUAL PAD100 NAC NAC MODULEfirealarmresources com

Related Files