NOTICE TO THE INSTALLER manual provides an overview and the installation instructions for the UD 2000 module terminals are power limited and should be wired in accordance with the requirements of NFPA 70 NEC and NFPA National Fire Alarm Code Failure to follow the wiring diagrams in the following pages will cause the system to not as intended For further information refer to the control panel installation instructions module shall only be installed with listed control panels Refer to the control panel installation manual for proper operation DESCRIPTION UD 2000 Digital Alarm Communicator Transmitter DACT provides for up to two 2 phone lines for communication a monitoring station The UD 2000 DACT communicates using the SIA DCS or Ademco Contact ID protocols When the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect a remote receiver Once the communication is complete the DACT will hang up the phone line DACT is provided with terminal blocks for each phone line In order for the DACT to work properly it must be installed a plain old telephone service POTS or equivalent as deemed by the authority having jurisdiction The DACT must be before any other equipment to ensure it can seize the line and disconnect any other lines lines are high voltage and should be run in a separate conduit from other circuits The wire conductors connecting DACT to the phone system should be 26 AWG or larger the phone lines are connected to the control panel the phone lines are supervised The phone line are non power and should be routed accordingly comes factory addressed as address 1 comply with UL 864 10th Edition an alternate source of communication shall be used as the secondary means of and shall not be a phone line connecting a device to the RS 485 take the following precautions to prevent potential damage to the RS 485 or P Link or device Power to the UD 2000 connection is removed Field wiring on module is correctly installed Field wiring has no open or short circuits TECHNICAL SPECIFICATIONS Current Current Temperature Range Humidity Range no of UD 2000 Expanders WxHxD mA mA to 120 0 to 49 C non condensing x 6 x 1 5 8 INSTALLATION P4 and UD 2000 P1 The connection is power limited and supervised The UD 2000 must be mounted in the panel cabinet The wiring diagrams shown below illustrate where to connect The connection is power limited and PAGE 1 OF 3 Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com5406324 REV A 6 18INSTALLATION MANUAL UD 2000 DIGITAL ALARM COMMUNICATORfirealarmresources com 1 EXAMPLES OF WIRINg A uD 2000 WITH P CONNECTOR ON SMALL PLATFORM CONTROL PANEL in guides under main board 593 32A Connector main board in guides under main board 593 32A Power system down Slide the UD 2000 DACT into the card guides located under the User Interface bracket Secure the UD 2000 DACT to the User Interface bracket using the provided 6 32x3 8 screw 1 shown above the provided four wire 4 conductor jumper P N 5210514 between UD 2000 P1 and P4 2 uD 2000 2 RING 2 RING 1 RING 1 RING PAGE 2 OF 3 Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com5406324 REV A 6 18 INSTALLATION MANUAL UD 2000 DIGITAL ALARM COMMUNICATORfirealarmresources com 3 EXAMPLE OF WIRINg A uD 2000 MODuLE WITH P CONNECTOR ON LARgE PLATFORM CONTROL PANEL Connector main board E 1 1 Wire preparation strip all wires 1 4 inch from their edges as shown here Stripping too much insulation may cause a ground fault Stripping too little may cause a poor connection and subsequently an open circuit inch D 1 1 B 1 1 instructions do not purport to cover all the details or variations in the equipment described nor provide for every contingency to be met in connection with installation operation and maintenance Technical Assistance contact Potter Electric Signal Company at 866 956 1211 the matter should be referred to a distributor in your region PAGE 3 OF 3 Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com5406324 REV A 6 18 INSTALLATION MANUAL UD 2000 DIGITAL ALARM COMMUNICATORfirealarmresources com