Potter IPA-4000 Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name potter-ipa-4000-fire-alarm-control-panel-2016973458.pdf
Type PDF
Size 1.07 MB
Downloads

Text Preview

Features addresses available on this analog addressable system system capacity achieved via multi point SLC modules software zones 72 Compliant Smoke Sensitivity Test Built In Operates as Class A or Class B for SLC P Link and NACs Amp Power Supply Expandable to 315 amps NACS Regulated Rated at 3 Amps each expandable to 192 Input Output I O Circuits for system flexibility rated at 1 Amp each for manual release and abort Synchronization and System Wide Sync for Potter AMSECO Cooper Wheelock and System Sensor strobes Alarm Supervisory and Trouble Relays Event History Buffer will house up to 18 AH batteries two line DACT with UD 2000 that can report General Zone or Information in IP communicator Port for Programming and Network Connectivity System Status Reports and Event Information includes 5 year warranty Listed for Smoke Control IPA 4000 is an expandable analog addressable releasing fire alarm with a total system capacity of 4,064 addresses Additional on the system is achieved using multi point SLC modules control panel utilizes the exclusive Potter protocol that includes a line of sensors and modules The system is expandable with a of thirty one additional addressable Signaling Line Circuits SLC with a maximum of 127 devices Each SLC may be comprised of any of smoke sensor heat detectors or modules and allows for a of 50 ohms of impedance and may use any wire compliant with the Electrical Code NEC IPA 4000 has a 10 Amp power supply with six Notification Circuits NACs and four Input Output I O circuits The are rated at 3 Amps each and the I Os are rated at 1 Amp each output is regulated and power limited In addition each output is programmable and may be configured for steady signal strobe constant power door holder power or releasing The synchronization includes Potter AMSECO Gentex System Sensor Cooper Wheelock and with the exclusive Quadrasync each output have a unique brand and all strobes will flash together The I Os are for inputs such as manual release stations and abort switches that not require polling and react nearly instantaneously IPA 4000 is listed for releasing of fire suppression systems The allows cross zones counting zones and timers for suppression system is capable of multiple release outputs across multiple hazards addition the PSN 1000 may be used to extend releasing capability NACs may be expanded using the PSN 1000 series intelligent power Each PSN 1000 adds another 10 Amps of power 2 additional circuits and the IPA 4000 will support up to 31 power supplies The will synchronize the strobes system wide In addition the PSN has space to allow the installation of up to six PAD100 SLCE SLC expansion cards The cards mount on a stacker bracket that allows to all SLC circuit connections Fire Dept of Approval Specifications Mains and Range 15 16 x 27 5 16 x 4 7 16 Amps 120 VAC 50 60 HZ Amps 240 VAC 50 60 HZ gauge cold rolled steel with removable door with Lexan viewing window Current 130 mA Current 220 mA 10 Amps power for NACs I O and P Link 3 Amps per NAC regulated 1 Amp per I O circuit regulated Battery Charger range 8 55 Ah Battery Charger voltage 27.3 VDC P Link maximum current of 1 Amp to 120 0 to 49 with a maximum of 93 non condensing NFPA 12 12A 13 15 16 17 17A 70 92 750 and 2001 ANSI UL 864 Local L Remote Station Central Station CS Propriety Auxiliary AUX Type of Service A Manual M Water flow Sprinkler Supervisory SS Type of Digital Alarm Communicator March Time March Non Coded Reverse Polarity Rev Pol Other OT International Building Code PAGE 1 OF 5 Alarm Control Panel8830102 REV H 2 22Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Loop Accessories control panel may be connected with up to 4,064 addressable devices or modules in any combination The SLC is not restricted by any special requirements and may be wired with any wire that complies with the NEC Loop Devices Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.0 to 3.7 foot UL 268 7th Edition Analog Photoelectric Smoke Heat Detector a smoke detector with a listed obscuration of 1.0 to 3.5 foot and a fixed temperature range of 135 to 185 F heat detector Smoke detection compliant with UL 268 7th Edition Photoelectric Smoke Carbon Monoxide Detector Smoke detection compliant with UL 268 7th Edition Carbon detection compliant with UL 2075 Photoelectric Smoke Heat Carbon Monoxide Detector Smoke detection compliant with UL 268 7th Edition Heat with a fixed temperature range of 135 to 185 F and is UL 268 and UL 521 7th Edition compliant Carbon Monoxide compliant with UL 2075 Fixed Temperature 135 185 or Rate of Rise Heat Detector software selectable Addressable Duct Smoke Detector with Form C Relay rate at 10Amps 250 120VAC or 8 Amps at 30VDC Duct Smoke Detector round base that is mounted to an electrical box and wired for connection of one of the above sensors round base that may be mounted to an electrical box and wired for connection to the above sensors base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop Relay Base that contains one relay controlled by the SLC Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC Sounder Base that contains an addressable sounder module that may be configured for local group and all call CO gas detector photoelectric smoke detector for use in DUCT DUCTR enclosure Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local group and all The LFSB complies with the Low Frequency Signal Requirements 520 Hz base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1 8W to 4W PAGE 2 OF 5 REV H 2 22Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comIPA 4000Fire Alarm Control Panelfirealarmresources com Input Module provides a small foot print contact module for mounting inside an enclosure Action Addressable Pull Station Dual Action Addressable Pull Station Input Module is a standard contact module with an LED that mounts into a 4 square electrical box Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode Relay Two Input module provides two form C relays that are individually controlled by the control panel Each relay is rated for 2 at 30VDC or 0.5 amps at 125VAC Also provides two contact inputs Appliance Circuit module is an addressable remote appliance circuit controlled by the panel Module is used to connect conventional 2 wire smoke detectors to the system Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop Module that provides one form C relay controlled by the control panel Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC provides a single addressable LED that is controlled by the control panel Module provides switching for two audio channels Addressable LED and key switch that mounts in a single gang box Remote Test Switch that mounts in a single gang box and optionally supervised Relay One Input Module provides one form C relay and one input The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC PAGE 3 OF 5 REV H 2 22Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comIPA 4000Fire Alarm C

Related Files