Potter LGTSM SYNCHRONIZATION CONTROL MODULE InstallationManual

File Preview
File Preview
Click below to download for free

Text Preview

GTSM SYNCHRONIZATION MODULE CAN ULC COMPLIANT CAN ULC LISTED PRODUCT INFORMATION IS FOUND ON PAGE 4 INTRODUCTION Potter Electric Model GTSM control module is designed to provide an easy way to synchronize multiple strobes and horn strobes using only two wires The GTSM is compatible with the Series FEP SEP Series SPKSTR 24WLP strobe Series SPKSTR 24CLP strobe Series CSPKSTR AL WP strobe Colored Lens Series CSPKSTR AL strobe Colored Lens CS 24 strobe only Series CCS 24 strobe only Colored Lens Series S24 177 strobe only Series S 24 WP SLP 24 WP strobe only Series CS 24W WP CSLP 24W WP strobe Colored Lens Series S 24 strobe only Series et CS 24W strobe only Colored Lens Series The control module has the capability to synchronize multiple horn signals with a code 3 pattern a code 4 temporal pattern and the ability to silence the horn while allowing the strobes to continue to flash By incorporating the control module as shown in the following the module will control the power to the units to produce the synchronized operation WHEN USING TWO WIRE OPERATION AND WHEN SWITCHES ARE PRESENT ON THE SIGNALS SWITCHES 1 AND 2 ON THE SIGNALS MUST BE IN THE ON POSITION ON THE SIGNALS ARE IN THESE POSITIONS WHEN SHIPPED FROM THE FACTORY FEATURES OF THE GANGABLE GTSM CONTROL MODULE Slave control modules sync input is wired to the master control module output as an ordinary signal This allows the user to determine which module will act as the master which module s will act as the slave s Electrically isolated control module sync input allows slave control modules to be connected across separate power supplies and panels Wiring between sync modules to maintain synchronized operation sync and terminals is supervised Sync input terminals and horn input terminals present a load of 7mA at 24VDC to the power supply Slave control module sync terminals are connected to the output of the master sync control module in the same manner as an ordinary signal Loss of sync signal on slave module failsafe mode If a control module set up as a slave loses the sync signal from the master the slave module will revert to independent operation The horns on zones controlled by a slave module may be independently muted via the horn input on the slave module If the master control module receives a mute signal all slave modules and their corresponding zones are placed into mute mode Staggered zone power up with synchronization is possible If any slave module receives power after the master sync module all units will re sync with the master module four seconds A green LED status indicator will flash once every four seconds if zone 1 is operational The LED will flash twice every four seconds if zones 1 and 2 are operational See table in Class B wiring diagrams for master synchronization input operation THE MASTER CONTROL MODULE MUST BE POWERED AT THE SAME TIME OR PRIOR TO THE POWERING OF THE SLAVE MODULES FOR PROPER OPERATION DO NOT USE THE GTSM WITH MHT 1224 EH 24 HS24 177 HS 24 COLORED LENS SERIES CHS 24 HS 24 WP HSLP 24 WP COLORED LENS SERIES CHS 24 WP CHS 24 COLORED LENS SERIES CCHS 24 IF ONLY ONE SET OF INPUT TERMINALS ARE USED THEY MUST BE IN1 OUT1 AND NEG1 FOR THE CONTROL MODULE TO OPERATE Synchronization Module Sound Output Settings 3 4 must have 24 VDC power from F A C P produce Temporal 3 sound output must have zero voltage from F A C P produce Temporal 4 sound output and NEG1 must have 24 VDC power from fire alarm contol panel output to operate diagram of synchronization including status SYNC OUT1 NEG1 OUT2 NEG2 CLASS B WIRING DIAGRAM OF LINE FOR B ONLY JUMPER IF HORN SILENCE IS USED JUMPER IN TO ELIMINATE FOR HORN INPUT GTSM 1 2 SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H OF LINE FOR B ONLY CROSSING DO NOT 1 WIRING FOR MULTIPLE CLASS B CIRCUITS AND USE OF A SLAVE MODULE 1 2 3 4 5 OF LINE FOR B ONLY SYNC OUT1 NEG1 OUT2 NEG2 OF LINE FOR ONLY B JUMPER IF HORN SILENCE IS USED JUMPER IN TO ELIMINATE FOR HORN INPUT GTSM diagram of synchronization including status SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H 3 OF LINE FOR B ONLY SYNC OUT1 NEG1 OUT2 NEG2 2 JUMPER IN ON SLAVE UNITS SEPARATE HORN CIRCUIT NEEDED SIGNAL S H SIGNAL S H OF LINE FOR B ONLY SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H OF LINE FOR B ONLY OF LINE FOR B ONLY 4 5 Module Sound Ouput Settings 1 2 3 4 5 3 4 CROSSING DO NOT 2 WIRING FOR MULTIPLE CLASS B CIRCUITS AND USE OF A SLAVE MODULE 1 2 3 4 5 6 7 8 9 diagram of synchronization including status SYNC OUT1 NEG1 OUT2 NEG2 OF LINE FOR ONLY B OF LINE FOR ONLY B JUMPER IF HORN SILENCE IS USED JUMPER IN TO ELIMINATE FOR HORN INPUT GTSM SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H OF LINE FOR B ONLY JUMPER IN PLACE ON UNITS UNLESS SEPARATE SILENCE CIRCUIT IS NEEDED SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H SYNC OUT1 NEG1 OUT2 NEG2 SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H 3 4 5 6 7 2 8 9 OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H OF LINE FOR B ONLY SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H Module Sound Ouput Settings 1 2 3 4 5 3 4 CROSSING DO NOT 3 ELECTRICAL SPECIFICATIONS 24VDC Max Current 24VFWR Max Current mA mA DC VOLTAGE RANGE LIMITS 16 33V FWR VOLTAGE RANGE LIMITS 16 33V THIS PRODUCT WAS ONLY TESTED TO THE STATED VOLTAGE RANGE S DO NOT 80 AND 110 OF THIS RANGE FOR SYSTEM OPERATION UNITS HAVE BEEN TESTED TO 0 49 AND 93 HUMIDITY The GTSM is to be connected only to circuits that provide continuously applied voltage Do not use this module on coded or interrupted circuits in which the voltage is cycled on off The GTSM has terminals which can accept wire sizes from 12 to 18AWG with

Related Files