Potter NGP-300D Installation, Operation, & Service Manual

File Preview
File Preview
Click below to download for free

File Data

Name potter-ngp-300d-installation-operation-service-manual-8723015946.pdf
Type PDF
Size 7.60 MB
Downloads

Text Preview

NGP 300D Operation Service Manual Electric Signal Company LLC Louis MO Service 866 240 1870 Technical Support 866 956 1211 Fax 314 595 6999 5401568 A NGP 300Dfirealarmresources com of Contents 4 Overview 6 Going to the Job Site 9 and Inspection 10 of Nitrogen Generator 11 of NGP 300D 12 of Nitrogen Purging System 13 Air Filling Method 14 Purging Procedure 17 Control Module 20 Generator Alarms Troubleshooting 21 Generator Leak Check Method 23 Side Leak Check Method 24 Membrane Check 25 System Leak Check 26 Maintenance 27 Operating Parameters of the NGP 300D 29 Analyzer Instructions 30 Diagrams 33 Specifications and Drawings 35 36 NGP 300Dfirealarmresources com Safety Guidelines manual contains safety information that is important to know and understand This information is provided for the safety installers operators and users of the Potter Nitrogen Generator To help recognize this information observe the following indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury indicates important information that if not followed may cause damage to equipment or property Notice to Users Installation and Owner Manual supplied with each unit must be read thoroughly and completely understood before and operation of the Potter Nitrogen Generator All appropriate safety standards for handling of gases as determined local or national laws and regulations should be followed at all times unpacking unit carefully inspect all parts and equipment for any damage that may have occurred during transit Make sure tighten fittings bolts etc before putting unit into service not operate if damage occurred during shipping handling or Contact Potter immediately Safety Information Read all of the safety information in this manual before operating this equipment Use of the equipment in a manner specified within this manual may impair the protection provided by the generator and could result in an unplanned release of which may cause serious injury or damage Only competent personnel who have been trained qualified and approved Potter Electric Signal Company should perform commissioning servicing and repair procedures handling installing or operating this equipment personnel must employ safe engineering practices and observe all related regulations health and safety procedures and legal requirements for safety that the equipment is depressurized and electrically isolated before carrying out any of the scheduled maintenance specified in this manual NGP 300Dfirealarmresources com warnings in this manual cover the most known potential hazards but by definition cannot be all inclusive If the user employs operating procedure item of equipment or a method of working that is not specifically recommended by Potter Electric Signal the user must ensure that the equipment will not be damaged or become hazardous to persons or property is not a poisonous gas However in a concentrated form there is a risk of asphyxiation The generator produces a flow nitrogen and oxygen enriched air which quickly disperses in the atmosphere However do not directly inhale the output gas the outlet pipe generator is classified as non hazardous for transportation purposes and as non flammable for fire regulations This equipment for indoor use only Do not operate outdoors of the nitrogen membrane separator above the design pressure may be hazardous Do not connect it compressed air sources that can exceed its maximum pressure without installing appropriate pressure and safety relief devices in the compressed air line procedures must be developed for maintenance of the equipment on which the membrane separator is located labels must be continuously displayed in all areas where personnel might be exposed to a nitrogen atmosphere normal or upset condition not attempt to disassemble the nitrogen membrane Equipment damage may occur and cause the to function incorrectly NGP 300Dfirealarmresources com System Overview Potter Nitrogen Generator operates using membrane technology The smaller oxygen and water vapor molecules can pass permeate the membrane quickly The larger nitrogen molecules are less likely to diffuse through the separator tubes they continue downstream to the separator outlet The permeated molecules are discharged to the atmosphere through a in the separator casing Potter Nitrogen Generator is specifically designed to provide clean dry high purity nitrogen for use in fire protection systems The generator is a fully assembled package ready to be connected to a new or existing fire sprinkler system a factory pre engineered air compressor These turn key systems include all air filtration equipment required to keep the operating at peak efficiency 1 NGP 300D System Diagram INLET HANDLE MICRON VALVE HANDLE TANK HANDLE TEST PORT VALVE HANDLE CONNECT DRAIN TO ANALYZER NGP 300Dfirealarmresources com 2 Typical NGP 300D External View 8 Air Compressor Air Tank Pressure Gauge Air Tank Pressure Switch Air Storage Tank Nitrogen Storage Tank Nitrogen Cabinet Power On Light Nitrogen Solenoid Light Alarm Light Alarm Horn Membrane Pressure Gauge Nitrogen Tank Pressure Gauge NGP 300Dfirealarmresources com 3 Typical NGP 300D Internal View Nitrogen Membrane Nitrogen Control Panel Filter Drain Solenoid Test Bypass Valve Yellow Handle Bypass Alarm Swi

Related Files