Potter P2 Series High Security Contact installation

File Preview
File Preview
Click below to download for free

File Data

Name potter-p2-series-high-security-contact-installation-3157604928.pdf
Type PDF
Size 1.01 MB
Downloads

Text Preview

POTTER HSS INSTALLATION INSTRUCTIONS All Models of P2S P2D 000 Series POTTER MAGNET MODULES AND ANTI REMOVAL MAGNETS ARE EXTREMELY POWERFUL TAKE PRECAUTIONS TO AVOID THE MAGNETIC ATTRACTION OF SHARP TOOLS AND TO AVOID INJURY THE PINCHING FORCE BETWEEN THE MAGNET AND FERROUS METALS OR OTHER MAGNETS Tools and Components by Installer drill bits 35 21 3 16 screwdriver or a Phillips bit for use in the drill bit driver or any linear measuring instrument center punch hammer for more accurate hole locations may be used pilot drill bit for screws 3 32 or smaller may be used 1 16 SPACERS 10 BAG POTTER P N SP062 by Manufacturer per module set HSS switch module HSS magnet module switch magnet module self tapping screws 10 32 x 2 self tapping screws 6 1 long HSS switch module template HSS magnet module template anti rotational threaded stud set screw 1 16 plastic spacer plates Removal Tamper magnet Magnet Spacer Removal Tamper caps SP062 STUD SCREWS SCREW SCREW MODULE SCREW SCREWS SCREW SCREWS Current 0.25 A Resistive Voltage 30 VDC Power 25 W Resistive for outdoor use Potter HSS Level 2 series is to be connected to a UL compatible control panel for applications and a ULC Listed control panel for applications Series Loop Loop Tamper the Magnet Tamper here with a powerful Series Loop Loop Tamper to test Pry Tamper Plan Face mounted HSS for an ingress door Plan Top surface mounted HSS for an egress door MODULE SPACER SPACER TO FRAME FRAME TO to mount the switch module to the door frame close to the gap and without door swing interference The module must be mounted directly below the switch may be used to attain sufficient alignment placement for the set is 8 inches from the latch of the door at the top The operating gap must not 3 16 Provided templates may assist locating holes gap up to 1 8 is required for compliance with UL634 2 C634 high security standard to mount the switch module to the door stop close to the but without door closure interference The magnet module be mounted directly below the switch Spacers may be to attain sufficient alignment Recommended placement the set is 8 inches from the latch side of the door at the top operating gap must not exceed 3 16 Provided templates assist locating holes A gap up to 1 8 is required for with UL634 Level 2 C634 high security ingress door instructions egress door instructions clearance hole for the anti rotational screw must be drilled into the door frame before mounting the switch module its position is on the templates For anti tamper purposes the switch module has two sites for an anti rotational threaded stud only one will be used depending on which installation plan is chosen Thread the screw into hole until about 1 4 of the screw remains the module OF ANTI SCREW FOR DOOR ONLY SIDE OF THE SWITCH MODULE OF ANTI SCREW INSWINGING DOOR ONLY PERIMETER SWITCH M M FACE M M screw pilot drill all hole locations The single clearance hole the anti rotational screw must now be drilled to 3 16 or diameter Drill the 3 mounting hole locations for the 10 21 bit Drill the Removal Tamper screw location the 6 screw 35 bit Hold the switch module in position each screw in until seated securing the device CAUTION Potter magnet module and anti removal are extremely powerful Take precautions to avoid magnetic attraction between the magnet and ferrous or other magnets Align the magnet module below the switch module Determine whether spacers needed to achieve mounted alignment of the modules the magnet module and any necessary spacers in Drill the 4 hole locations for 10 screws 21 bit each screw in location until each has seated securing device the Removal Tamper magnet and then the Removal plug into the 3 8 hole at the face of the switch module The Magnet Spacer is not used in this installation the gap between modules The mechanical installation the set is complete pilot drill all hole locations The single clearance hole the anti rotational screw must now be drilled to 3 16 or diameter Drill the 2 mounting hole locations for the 6 35 bit Hold the switch module in position Drive each in until seated securing the device CAUTION Potter magnet module and anti removal are extremely powerful Take precautions to avoid magnetic attraction between the magnet and ferrous or other magnets Align the magnet module below the switch module Determine whether spacers needed to achieve mounted alignment of the modules the magnet module and any necessary spacers in Drill the 4 hole locations for 10 screws 21 bit each screw in location until each has seated securing device the Magnet Spacer the Removal Tamper magnet and the Removal Tamper plug into the 3 8 hole at the face of switch module Check the gap between modules The installation of the set is complete mounting hardware resistor configurations cable lengths and other variants are available 5673021 6603378 Pending 5403555 REV C Electric Signal Co LLC 5757 Phantom Dr Suite 125 Hazelwood MO 63042 tel 866.240.1870 fax 314.595.6999 www pottersignal com

Related Files