Potter PAD100-DIM Dual Input Module

File Preview
File Preview
Click below to download for free

File Data

Name potter-pad100-dim-dual-input-module-1928634057.pdf
Type PDF
Size 1.16 MB
Downloads

Text Preview

Features Single module with dual contact monitoring inputs Two 2 Class B or one 1 Class a monitoring inputs SLC Class a Class X Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty UUKL Listed for Smoke Control This addressable module does not support 2 wire smoke paD100 DIM uses one 1 SLC loop address when monitoring 2 Class B circuits or one 1 Class a circuit The module mounts either a 4 square or double gang box The module is capable monitoring two 2 separate class B circuits making it ideal for sprinkler waterflow and valve tamper switches when they located in the same proximity The PAD100 DIM includes one red to indicate the module status In normal condition the LeD when the device is being polled by the control panel When an is activated the LED will flash at a fast rate paD100 DIM is compatible with potter Ipa and aFC aRC addressable fire alarm control panels The PAD100 DIM is an module used to monitor dry contact devices such as sprinkler valve tamper switches or conventional pull stations The is capable of monitoring two separate Class B or one Class a the Address addressable SLC device must be assigned an address The is set using the DIP switch located on the PAD100 DIM When PAD100 DIM is used to monitor two individual Class B circuits single device address is assigned each input is then identified as a of the module address For example if the address number assigned as the first input will be and the second input be connecting a device to the SLC loop take the following to prevent potential damage to the panel or device Power to the device is removed Field wiring is correctly installed Field wiring has no open or short circuits Specifications Voltage SLC Standby SLC alarm Wiring Resistance IDC Wiring of IDC Resistor Temperature Humidity no of Module per units to 120 0 to 49 to 93 non condensing Options Weight 106mm L 4.17 1.14 29mm D 4 Square or gang Box lbs page 1 OF 2 Input Module8830082 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Using Compatible Electrical Box 1 THE DIP SWITCH POSITION CLASS A WIRING THE DIP SWITCH POSITION CLASS B WIRING Diagrams With One Class A Circuit 2 FACP OR MODULE NEXT MODULE RESISTOR NOT REQUIRED With Two Class B Circuits 3 FACP OR MODULE NEXT MODULE OHM 1 3005013 OHM 1 3005013 Information Input Module No page 2 OF 2 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD100 DIMDual Input Modulefirealarmresources com

Related Files