Potter PAD100-OROI One Relay One Input Module

File Preview
File Preview
Click below to download for free

File Data

Name potter-pad100-oroi-one-relay-one-input-module-0984316752.pdf
Type PDF
Size 1.12 MB
Downloads

Text Preview

Features One 1 Class B monitoring input One 1 Form C relay contact SLC Class a Class X Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box all wiring terminals accept 22 to 12 aWg product includes a 5 year warranty UUKL Listed for Smoke Control This addressable module does not support 2 wire smoke paD100 OROI uses one 1 SLC loop address when monitoring 1 Class B circuit and providing one 1 Form C relay contact module mounts on either a 4 square or double gang box The is capable of monitoring one 1 Class B circuit The paD100 includes one red LeD to indicate the module status In normal the LED flashes when the device is being polled by the panel When a the input is activated the LED will flash at a rate is compatible with potter Ipa and aFC aRC addressable fire alarm control panels The PAD100 OROI is an module used to monitor dry contact devices such as sprinkler valve tamper switches or conventional pull stations The is capable of monitoring one Class B circuit The paD100 also provides one 1 form C relay contact the Address addressable SLC device must be assigned an address The is set using the DIp switch located on the paD100 OROI the paD100 OROI is used to monitor one Class B circuit single device address is assigned the input and relay are then as a sub point of the module address For example if the number is assigned as the RLY1 relay will be and IN1 input will be connecting a device to the SLC loop take the following to prevent potential damage to the panel or device power to the device is removed Field wiring is correctly installed Field wiring has no open or short circuits 30VDC 0.5a 125VaC Specifications Voltage SLC Standby SLC alarm Contacts Wiring Resistance IDC Wiring of IDC Resistor Temperature Humidity no of Module per units to 120 0 to 49 to 93 non condensing Options Weight 106mm L 4.17 1.14 29mm D 4 Square or gang Box lbs page 1 OF 2 Relay One Input Module8830081 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Using Compatible Electrical Box 1 Diagram With One Class B Circuit 2 FACP OR MODULE RESISTOR OHM 1 2 W 3005013 1 FORM C CONTACT is possible that the internal relay in the paD100 OROI may be shipped in the non normal activated state To ensure that the internal relay is set to the state connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output Information No Relay One Input Input Module 3992702 page 2 OF 2 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD100 OROIOne Relay One Input Modulefirealarmresources com

Related Files