Potter PAD200-DUCTR Analog Addressable Duct Detector

File Preview
File Preview
Click below to download for free

File Data

Name potter-pad200-ductr-analog-addressable-duct-detector-8764902153.pdf
Type PDF
Size 1.16 MB
Downloads

Text Preview

Features Detects smoke in building HVAC ducts complete with housing and head with addressable IPA and AFC ARC series panels Class A Class X Class B without removing the head Air Velocity of 100 to 4,000 ft minute No screens or filters in housing Durable plastic enclosure and clear cover Utilizes simple snap in sampling tubes STN series One form C relay cover tamper switch with supervised PAD100 DRTS remote test switch MS KA R MS KA P R remote indicators includes a 5 year warranty UUKL Listed for Smoke Control PAD200 DUCTR is designed and built to meet all local as well as the NFPA regulations regarding duct smoke Air sampling is accomplished by two tubes which protrude the duct An exhaust tube of one standard length 7 is supplied the installation kit with the smoke duct unit Once the duct width been determined the air intake sampling tubes must be ordered tubes are supplied in three standard lengths 2.5 ft 5 ft 10 ft and cut to size to fit the duct Mounting the duct smoke is accomplished by the use of a template and 2 sheet metal which are provided Mounting can be achieved without the of the clear cover which is secured by 4 capture screws Potter Electric PAD200 DUCTR duct smoke detector provides detection of smoke and products of combustion present in moving through HVAC ducts in commercial industrial and applications The PAD200 DUCTR is compatible with IPA and AFC ARC series addressable fire alarm control panels Specifications Detector Model Voltage Draw Head Model Head Type Set Point Test Method Velocity Temperature VDC at 2.5 ft diagnostic test to 4000 ft min to 120 0 to 49 to 85 Relative humidity non backbox clear plastic cover backbox with clear cover 1 2 x 4 1 2 W x 2 1 4 H lbs ft 5 ft or 10 ft 10A 120VAC Material Net Weight Tubes contact rating PAGE 1 OF 2 Addressable Duct Detector8830166 REV A 3 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Specifications duct smoke detectors shall be Potter Electric PAD200 DUCTR Series The detectors shall be listed by Underwriters Laboratories per UL 268A detectors shall operate at air velocities from 100 feet per minute to 4000 feet per minute The duct detector housings shall be of plastic construction complete mechanical installation may be performed without removal of detector cover Visual indication of alarm and power must be provided on front Detector heads shall not require additional filters or screens which must be maintained The housing shall contain a detector base and duct smoke detector head Terminal connections shall be of the screw type and be a minimum of 12 screw All wiring must comply with codes and regulations Detector shall use the STN series of sampling tubes Diagrams Wiring 1 Wiring 2 FACP OR MODULE NEXT MODULE 24VDC PAD100 DRTS FACP OR MODULE NEXT MODULE FROM FACP OR MODULE TO FACP OR MODULE MS RA RED WIRE MS RA BLACK WIRE C RELAY 250VAC OPTION IN POSITION Jumper must be position when the MS KA P R C RELAY 250VAC OPTION Keep jumper in position when the PAD100 DRTS full wiring supervision Information Addressable Duct Detector W Remote Test Switch Annunciator Annunciator with Test Reset Annunciator with Test Switch Sampling Tube Sampling Tube Sampling Tube No No PAGE 2 OF 2 REV A 3 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD200 DUCTRAnalog Addressable Duct Detectorfirealarmresources com

Related Files