Potter PAD200-PD Photoelectric Smoke Sensor

File Preview
File Preview
Click below to download for free

File Data

Name potter-pad200-pd-photoelectric-smoke-sensor-9801725643.pdf
Type PDF
Size 907.24 KB
Downloads

Text Preview

Features UL 268 7th Edition Low profile less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 3.7 foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting no programming tool LED alarm indicator Product includes a 5 year warranty UUKL Listed for Smoke Control Photoelectric Smoke Sensor is a listed Analog Addressable smoke compatible with fire alarm control panels that utilize the Potter Device PAD protocol The PAD200 PD is a low profile sensor with a wide sensitivity range The sensor and base not are made of a durable plastic in an off white color to blend with the ceiling PAD200 PD has a sensitivity range of 1.0 to 3.7 per foot and UL The PAD200 PD features drift compensation and has built in detector warning as well as The PAD200 PD and the control communicate over a proven and robust digital communication and the system analyzes the information at the particular device total polling speed is less than five 5 seconds well under the UL sensor is compatible with any of the PAD series sensor bases and twists on The PAD200 PD is addressed using DIP switches the rear of the sensor and can be easily programmed in the field special tools the Address addressable device on the SLC loop must have a unique address 1 to 127 to function properly The address is set using DIP connecting a device to the SLC loop take the following to prevent potential damage to SLC or device Verify the to the device is removed wiring is correctly installed wiring has no open or short circuits VDC LED to 3.7 ft 3.6 12 m to 120 F 0 to 49 C to 93 Non condensing Specifications Voltage Current Draw indicator set point range temperature relative range time number of per loop number of indicators in per loop without base without 1 sec White 3.56oz 1.35 in 34mm 3.93 in 100 mm PAGE 1 OF 2 Smoke Sensor8830172 REV A 5 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Velocity Ratings PAD200 PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute system has a maximum of 30 LEDs that can be turned on simultaneously If the system already has 30 LEDs on the PAD200 PD will operate even the LED may not illuminate PAD200 PD is an analog addressable sensor that uses one address on the Signaling Line Circuit SLC of a compatible fire alarm control panel unit communicates with the control panel as it is polled The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is an active status The polling LED can be turned off if desired for less conspicuous operation PAD200 PD with the PAD100 4DB or PAD100 6DB has a low profile of less than two 2 inches to blend into the surrounding environment The includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector Sensitivity PAD200 PD and the compatible control panel work in tandem to keep the sensitivity consistent As the sensor is installed over time the sensor for the dirt in the unit until it is out of range At that time the panel will indicate a dirty sensor The sensor will then have to be cleaned replaced PAD200 PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to sensor going into trouble This allows for sensor replacement or cleaning prior to a nuisance trouble occurs As required by NFPA do not install the sensors until all construction is complete and the work area has been thoroughly cleaned If the sensors been installed in a construction environment they should be cleaned or replaced before the system is placed into service PAD200 PD is UL listed with a recommended maximum spacing of 30 feet Refer to NFPA 72 for specific information regarding detector spacing and special applications Bases bases will mount on a single gang double gang octagon 4 square or mud ring electrical box No Standard Base Standard Base base with an isolator module included base with one Form C relay contact 2A 30VDC 0.5A 125VAC base with sounder module included Sound pattern is provided from external source 3992729 base with speaker included Information Smoke Sensor No PAGE 2 OF 2 REV A 5 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD200 PDPhotoelectric Smoke Sensorfirealarmresources com

Related Files