Potter PSN-1000 & PSN 1000(E) Installation Manual

File Preview
File Preview
Click below to download for free

File Data

Name potter-psn-1000-psn-1000-e-installation-manual-2487695130.pdf
Type PDF
Size 2.17 MB
Downloads

Text Preview

PSN 1000 PSN 1000 E Manual Electric Signal Company LLC Louis MO Service 866 240 1870 Technical Support 866 956 1211 Fax 314 595 6999 5403599 Rev C 04 17 Installation Wiring Document 50Hz 60Hz 50Hz 60Hz to separate AC circuit SUPPLY BULK VAC Position AC 120VAC 50Hz 60Hz 5.1 AMP Min Low AC Detect 98VAC 240VAC 50Hz 60Hz 2 AMP Min Low AC Detect 194VAC Relays 3A 125VAC Resistive 3A 30VDC Resistive Charging 27.3VDC 1A Low Battery Detect 20.4VDC Fault to Any Terminal 0 Ohms Specification 8A 250VAC Time Lag 5409083 B 12 21 2016 LOW AC COM NO TROUBLE COM NO relays are limited I2 NAC2 NAC4 NAC6 I1 NAC1 NAC3 NAC5 IN A B P LINK OUT A B RPTR MAIN P LINK A B REPEATER FROM PANEL device has been verified to comply with FCC Rules Part 15 A Operation is subject to the following conditions This device may not cause radio interference This device must accept any interference received including any that may cause undesired operation must be fully tested after installation for indoor use in dry locations only of power limited wiring from non power limited wiring must be at least 1 4 in accordance with installation manual Part Number 5403599 Rev 70 72 12 12A 13 15 16 17 17A 750 2001 De Energize Unit Prior to Servicing connection non power limited two 2 12V batteries connected in series of Circuit Connection Connection Relay AC Relay Device Circuits NACs Circuits RS 485 Connections Type Voltage Voltage Voltage Voltage Voltage Voltage Voltage Type Limited Limited Limited Limited Limited Limited Limited POWER EXPANDER 5403599 REV C 04 17firealarmresources com Supply Circuit AC terminals are located on the power supply board The power supply board supervises the main AC and provides indication that the AC power is absent 50 60 Hz 50 60 Hz to separate AC circuit G POWER AC230V 50 60Hz 1 terminals are rated at 120 VAC 240 VAC 50 60 Hertz and are marked so accordingly on the board The ground connection is marked as and is the furthest connection from the line voltage connection AC input power ratings of 5.1A at the nominal 120 VAC rating of 3A at the nominal 240 VAC rating Battery Circuit battery charging circuit is provided on the power supply board Terminal connections are provided to con wire leads for battery connection The battery must be a recognized or listed sealed lead acid battery or battery charging voltage is approximately 27.3 VDC and the circuit is supervised The battery circuit is with a non replaceable 7 amp poly switch located on the main circuit board The maximum battery circuit is 1.0 amp DC battery circuit is rated for 8 to 55 AH batteries and the cabinet will house up to two 18 AH batteries The will operate the panel for at least 24 hours and 5 minutes of alarm In order to determine the minimum batteries for standby and alarm times desired the installer must complete a battery calculation work sheet order to determine the minimum battery size for a particular application For reference the battery calcula work sheet is attached as Appendix A Complete standby battery calculations must be completed to ensure battery sizes are provided POWER EXPANDER 5403599 REV C 04 17firealarmresources com V V 2 of Circuits Power Limited Non Power Limited High Voltage Wiring main AC power connection is considered high voltage and non power limited Battery conductors and alarm supervisory and trouble relays are non power limited All remaining circuits are low voltage power connections separation must be maintained between the circuits listed above All separations in the different wiring be maintained by at least 0.25 inches and the wire insulation must be for the higher voltage the enclosure there are sufficient knock outs located around the periphery of the cabinet to allow the installer maintain separation between power limited and non power limited connections The main AC power connec should be made on the left side or top left of the cabinet Appliance Circuits NACs PSN 1000 is equipped with six NAC circuits Each of the circuits is rated for a continuous 3 amps at 24 The outputs are supervised and regulated The NACs reverse polarity upon activation and the board and are marked accordingly NAC circuits can be configured for Class A operation Class A operation is accomplished by using a pair of circuits Therefore the PSN 1000 can provide 3 Class A circuits each rated for a continuous 3 amps at 24 The outputs are supervised and regulated circuits are power limited and the type of output is selectable The NACs may be configured for strobe with Potter AMSECO Wheelock Gentex or System Sensor strobe devices as shown compat in this document and the installation instructions maximum impedance is a function of the load being applied to the circuit In order to calculate the maxi impedance as follows Current of Notification Appliances X Wire Resistance 3 volts NAC circuits may be configured for Class A Style Z or Class B Style Y panel has ground fault detection on the NAC circuits The impedance to ground for ground fault detection is ohms POWER EXPANDER 5403599 REV C 04 17firealarmresources com I2 NAC 2 NAC 4 NAC I1 NAC 1 NAC 5 NAC EOL Part 3005013 3 Class B NAC end of line resistor is a 5.1K ohm resistor The resistor assembly has been evaluated in past projects and a standard in the Potter panel product line The Potter part number for the listed end of line assembly is EOL Resistor Assembly POWER EXPANDER 5403599 REV C 04 17firealarmresources com I2 NAC 2 NAC 4 NAC I1 NAC 1 NAC 5 NAC 4 Class A NAC A operation requires that two NAC circuits be utilized as shown in Figure 4 Up to 3 Class A circuits can configured by pairing NAC 1 2 NAC 3 4 and NAC 5 6 POWER EXPANDER 5403599 REV C 04 17firealarmresources com Circuits panel is equipped with two input circuits I1 and I2 These circuits are dry contact monitoring inputs and be used in class B mode only I1 and I2 are low voltage power limited and supervised wiring resistance 100 ohms wiring capacitance 1 uF wire length 10,000 feet IDC voltage 24 VDC IDC current 15 ma panel has ground fault detection on the input circuits The impedance to ground for ground fault detection 0 ohms I2 NAC 2 NAC 4 NAC I1 NAC 1 NAC 5 NAC Open Contact EOL Part 3005013 5 Input Circuit as Class B Dry Contact Input end of line resistor is a 5.1K ohm resistor The resistor assembly has been evaluated in past projects and a standard in the Potter panel product line The Potter part number for the listed end of line assembly is EOL Resistor Assembly POWER EXPANDER 5403599 REV C 04 17firealarmresources com from Control Panel control panel communicates with the PSN 1000 via the main P Link circuit This connection is electrically from the rest of the PSN 1000 All supervision of the PSN 1000 is conducted through this connection A B from Control 6 Repeater P Link repeater output allows for system expansion by reconditioning and repeating all P Link communi The PSN 1000 repeater output provides an additional 1 amp at 24 VDC which can be used to power P Link devices such as LCD Annunciators and or SLC Loop expanders is fully supervised and power limited Any connection to ground of 0 ohms will be annunciated as a fault Current 1 Amp Each Voltage 24 VDC wire length 6,500 feet wire resistance Maximum

Related Files