Potter RTS-O RTS-C ROOM TEMPERATURE SWITCH

File Preview
File Preview
Click below to download for free

File Data

Name potter-rts-o-rts-c-room-temperature-switch-5236401987.pdf
Type PDF
Size 1023.67 KB
Downloads

Text Preview

RTS Mounting Template RTS C TEMPERATURE SWITCH RTS C TEMPERATURE SWITCH UL cUL Listed White ABS 2 1 16 W x 3 7 16 L x 1 1 4 H W x 7cm L x 3.2cm H sealed stainless steel case operating mechanism clad available normally or normally closed Rating 1 Amp at 24VDC Setting 40 4,5 Screw Terminals Wall Mount Surface RTS C TEMPERATURE SWITCH UL cUL Listed White ABS 2 1 16 W x 3 7 16 L x 1 1 4 H W x 8,7cm L x 3,2cm H sealed stainless steel case operating mechanism clad available normally or normally closed Rating 1 Amp at 24VDC Setting 40 4,5 996 3 Stock No 1010108 Stock No 1010109 IN USA 5401019 REV g 4 of 4 IN USA 5401019 REV g 1 of 4 RTS C TEMPERATURE SWITCH Mounting Template 996 3 Stock No 1010108 Stock No 1010109 Screw Terminals Surface IN USA 5401019 REV g 4 of 4 IN USA 5401019 REV g 1 of 4 IN USA 5401019 REV g 2 of 4 IN USA 5401019 REV g 3 of 4 The RTS does not have duplicate terminals Do not use looped wire terminals Break wire run to provide supervision of connections RTS C TEMPERATURE SWITCH normally open detector RTS O will close the contact when the drops below 40 4,5 The normally closed detector RTS C open the contact when the temperature drops below 40 4,5 The will automatically reset to the normal state when the temperature above 40 4,5 TESTING MAINTENANCE frequency of inspection and testing of the RTS and its associated system shall be in accordance with applicable local and NFPA and standards Manufacturer recommends quarterly or more test can be accomplished by spraying the RTS with circuit cooler equivalent accurate test requires exposing the RTS to 40 5 RTS requires no maintenance other than ensuring the vent holes are not RTS C TEMPERATURE SWITCH normally open detector RTS O will close the contact when the drops below 40 4,5 The normally closed detector RTS C open the contact when the temperature drops below 40 4,5 The will automatically reset to the normal state when the temperature above 40 4,5 TESTING MAINTENANCE frequency of inspection and testing of the RTS and its associated system shall be in accordance with applicable local and NFPA and standards Manufacturer recommends quarterly or more test can be accomplished by spraying the RTS with circuit cooler equivalent accurate test requires exposing the RTS to 40 5 RTS requires no maintenance other than ensuring the vent holes are not RTS C TEMPERATURE SWITCH RTS C TEMPERATURE SWITCH 1019 1 1019 1 Unit Device Unit Device Unit Device Unit Device IN USA 5401019 REV g 2 of 4 IN USA 5401019 REV g 3 of 4 The RTS does not have duplicate terminals Do not use looped wire terminals Break wire run to provide supervision of connections

Related Files