Potter VSR-SG Waterflow Alarm Switch with Glue-in Union

File Preview
File Preview
Click below to download for free

Text Preview

for CpvC pIpe type waterflow swItCH wItH retarD Glue In unIon Cul and CsfM listed Ce Marked pressure Up to 175 PSI 12,07 BAR sensitivity range for signal 4 10 GPM 15 38 LPM UL surge 18 FPS 5.5 m s ratings sets of SPDT Form C Amps at 125 250VAC Amps at 30VDC Resistive mAmps min at 24VDC entrances Two openings provided for 1 2 conduit switch compartments suitable dissimilar voltages Specifications NEMA 4 IP54 Rated Enclosure suitable for indoor or use with factory installed gasket and die cast housing used with appropriate conduit fitting Temperature Range 40 120 4.5 49 UL use Standard Sprinkler or two family dwelling occupancy up to four stories Fire Alarm Code Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances Shock hazard Disconnect power source before servicing Serious injury or death could result Risk of explosion Not for use in hazardous locations Serious injury or death could result 24 60 cm of a valve or drain The unit has a 1 male fitting gluing into a CPVC plastic tee Do not leave cover off for an extended period of time the union nut and separate the 1 male fitting from the VSR SG the 1 male fitting into the TEE following the TEE manufacturer for preparation and gluing of CPVC piping systems Note 1 male fitting must bottom out on the stop of the TEE for proper of the VSR SG See Fig 1 Wait 2 to 4 hours to allow the to dry before attaching the VSR SG to the 1 male fitting Select proper paddle for the pipe size and type of TEE used See Fig 3 instructions on how to change paddle verify that the o ring is positioned in its groove Hand tighten the nut on the union orienting the switch in the appropriate direction to detect waterflow shown in Fig 5 Fig 7 vane must not rub the inside of the TEE or bind in any way The should move freely when operated by hand subject to change without notice number 1144460 Cover Tamper Switch Kit stock no 0090148 Components Retard Switch Assembly stock no 1029030 switches that are monitoring wet pipe sprinkler systems shall be used as the sole initiating switch to discharge AFFF deluge chemical suppression systems Waterflow switches used for this may result in unintended discharges caused by surges air or short retard times Information Model VSR SG is a vane type waterflow switch for use on wet systems using CPVC plastic fittings manufactured by Tyco Victaulic Ipex and Spears Manufacturing Company that use 1 1 or 2 pipe sizes It is equipped with a union to accommodate in confined spaces VSR SG contains two single pole double throw snap action and an adjustable instantly recycling pneumatic retard The are actuated when a flow of 10 GPM 38 LPM or more downstream of the switch The flow condition must exist for a of time necessary to overcome the selected retard period VSR Sg switches and retard switch are enclosed in a general die cast housing The cover is held in place with two tamper screws which require a special key for removal A field cover tamper switch is available as an option which may used to indicate unauthorized removal of the cover See bulletin 5401103 for installation instructions of this switch see Fig 1 3 and 5 switches may be mounted on horizontal or vertical pipe On pipe they shall be installed on the top side of the pipe where will be accessible The switch should not be installed within 6 cm of a fitting which changes the direction of the waterflow or not trim the paddle Failure to follow these instructions may prevent the from operating and will void the warranty not over tighten the union nut hand tighten only Use of a wrench damage the union nut Electric Signal Company LLC St Louis MO Cust Service 866 572 3005 Tech Support 866 956 0988 Canada 888 882 1833 www pottersignal com IN USA PAgE 1 OF 4 5401205 REV H CpvC pIpe type waterflow swItCH wItH retarD Glue In unIon frequency of inspection and testing for the Model VSR SG and its associated protective monitoring system shall be in accordance with applicable Codes and Standards and or the authority having jurisdiction manufacturer recommends quarterly or more frequently method of testing the VSR SG must be provided The valve used for testing shall be easily reached and shall produce a minimum flow of 10 to activate the switch The discharge orifice shall be equal to the smallest sprinkler used in the system the person responsible for testing of the fire protection system that this system must be tested in accordance the testing instructions 2 out thin section of cover when wiring both switches from one entrance 1 the 1 male fitting into the TEE following TEE manufacturer instructions for and gluing of CPVC piping Wait 2 to 4 hours to allow the glue dry before attaching the VSR SG to the 1 fitting 1205 4 4 typical electrical Connections The Model VSR SG has two switches one can be used to operate a station proprietary or remote signaling unit while the other is used to operate a local audible or visual annunciator For supervised circuits see Terminal Connections and warning note Fig 6 FROM BREAKER FROM BELL FROM BREAKER End Of Line Resistor connecting to a UL Listed panel use the panel value for circuit supervision 3 paddles are furnished with each unit accommodate the various sizes and of TEES The paddles have lettering that show the pipe size and TEE manufacturer they are to be used The proper paddle must be used The must be properly attached see Fig 3 the screw that holds the paddle must be tightened IN USA 5401205 REV H PAgE 2 OF 4 CpvC pIpe type waterflow swItCH wItH retarD Glue In unIon 6 switch terminal Connections Clamping plate terminal 5 adjustment delay can be adjusted by rotating the retard knob from 0 to the max setting 60 seconds The time delay should be set at the required to prevent false alarms COVER TAMPER SWITCh not leave cover off for extended period of time SO ARROW ON POINTS IN DIRECTION WATERFLOW MALE FITTING ON SIZES 1205 1A OF THE TEE BE 1 1 1 or 2 uninsulated section of a single conductor should not be looped around the and serve as two separate connections The wire must be severed providing supervision of the connection in the event that the wire dislodged from under the terminal Failure to sever the wire may the device inoperable risking severe property damage and loss of life not strip wire beyond 3 8 of length or expose an uninsulated conductor the edge of the terminal block When using stranded wire capture all under the clamping plate 7 Mounting Dimensions orientation 8 in 141.2 mm 90 gROUND water activates switch in one only in 89.0 mm in 50.8 mm in mm PADDLE 1190 1 switch must be properly orientated Side of cover must be with the pipe Improper orientation could delay or prevent of waterflow IN USA 5401205 REV H 1205 15 PAGE 3 OF 4 CpvC pIpe type waterflow swItCH wItH retarD Glue In unIon the waterflow switch monthly If leaks are found replace the waterflow switch The VSR SG waterflow switch should provide years of service The retard and switch assembly are easily field replaceable In the unlikely event that either component does not perform please order replacement retard switch assembly stock 1029030

Related Files