Radionics - D2112 D2112E Installation Manual

File Preview
File Preview
Click below to download for free

File Data

Name radionics-d2112-d2112e-installation-manual-1608573429.pdf
Type PDF
Size 775.76 KB
Downloads

Text Preview

D2112 D2112E Control Communicator Manual 1 96 Installation Manual 1 1995 Radionics material and instructions covered in this manual been carefully checked for accuracy and are to be reliable However Radionics Inc no responsibility for inaccuracies and the right to modify and revise this manual notice a discrepancy is found in this documentation mail a photocopy of the corrected material to Communications Radionics Inc Abbott Street Box 80012 CA 93912 0012 1995 Radionics Inc Salinas CA U S A rights reserved Marking this version of the Installation Manual we added about the D2112E Control Communicator information about the D2112E appears the manual We marked changes to the design and operation of the panel a vertical line in the margin An example of the is shown in the margin to the left of this Notices 15 equipment generates and uses radio frequency If not installed and used in accordance with manufacturer instructions it may cause to radio and television reception It has tested and found to comply with the in Part 15 of FCC rules for Class B Devices this equipment causes interference to radio or reception which can be determined by the equipment on and off the installer is to correct the interference by one or of the following measures 1 Reorient the of the radio television 2 Connect the AC to a different outlet so the control panel radio television are on different branch circuits 3 the control panel with respect to the radio necessary the installer should consult an radio television technician for additional or send for the Handbook by the Federal Communications This booklet is available from the U S Printing Office Washington D C 20402 number 004 000 00450 7 68 equipment complies with Part 68 of FCC rules A contains among other information the FCC number and ringer equivalence number registered the D2112 Control for connection to the public telephone using an RJ38X or RJ31X jack the ringer equivalence number REN to the number of devices you can connect to telephone line Excessive RENs on the telephone may result in devices not ringing in response to incoming call In most but not all areas the sum the RENs should not exceed five 5 Contact the company to determine the maximum REN the calling area the D2112 Control Communicator causes harm to telephone network the telephone company will you in advance If advance notice isn the telephone company will notify the as soon as possible Also you will be of your right to file a complaint with the FCC you believe it is necessary telephone company may make changes in its equipment operations or procedures that affect the operation of the D2112 If this the telephone company will provide notice in order for you to make the modifications to maintain uninterrupted you experience trouble with the D2112 Control please contact Radionics Customer for repair and or warranty information If the is causing harm to the telephone network the company may request that you remove the from the network until the problem is resolved repairs must not be made Doing so voids the warranty not install the D2112 on public coin service by the telephone company Connection to Line service is subject to state tariffs Contact state public utilities commission for information must supply the local telephone company with following information at their request The line you are going to connect the panel to Make Radionics model D2112 and serial FCC registration number and ringer equivalence of the panel the panel Registration Number AJ9USA 20644 AL E Equivalence Center in USA Radionics Inc Abbott Street Box 80012 CA 93912 0012 538 5807 196 Installation Manual 2 1995 Radionics of Contents 2 Notices 2 4 Control Communicator 4 Separately 4 Options 4 and Approvals 4 Started 4 You Begin 4 the Enclosure 5 the Premises Wiring 5 Earth Ground 3 6 the Battery as You Work 6 the Standby Switch 6 1 and 2 6 4 and 5 6 Detection Devices Keypads and Bells 7 Connections to the Panel Yet 7 of Sensors 7 Connections the Panel 7 Down First 7 Output 6 and 7 7 8 9 and 10 8 Power 9 8 and Replacing D2112E Fuses 9 Relays 11 and 12 9 the Points 10 1 on the D2112 Only 13 and 14 10 2 to 6 1 to 6 on D2112E 15 to 22 14 to 22 on D2112E 10 7 and 8 on the D2112 Only 23 to 25 10 the Panel 12 the Telephone Connections 12 Up 12 out the Point Chart 12 the Standby Switch 12 the System 13 Panel Description 13 AC Power Circuit 13 DC Power 13 Outputs 14 14 15 15 Guide for UL Applications 17 17 Compatible Equipment 17 Rating Chart for Standby Battery Calcu 18 Battery Requirements 18 Chart 19 Wiring Diagram Issue A 20 21 Terminal Quick Reference 22 1 96 Installation Manual 3 1995 Radionics Control Communicator Radionics D2112 and D2112E Control are shipped pre assembled from the You should receive the following parts with D2112 or D2112E panel Options D2112 and D2112E are shipped in the D2103 If you want to mount the D2112 or in one of the optional enclosures listed order the D2112M or D2112EM and the of your choice Assembly D2112 or D2112E Panel D2103 Enclosure D1625 Transformer D2112 Only Smoke Detectors Compatible with D2112 Technogram 73 07115 000 Pack D2112 only One 2.0k W 1 30 01098 102 Five 1k W with D2112E 15 03130 008 end of line resistors for Points 2 to 6 end of line resistor for Two 6 by 3 8 sheet metal screws to secure D2103 Enclosure cover 60 03977 006 Separately Pack D2112 D2112E Installation Manual

Related Files