Radionics D7212spec Sheet

File Preview
File Preview
Click below to download for free

File Data

Name radionics-d7212spec-sheet-3719564028.pdf
Type PDF
Size 602.81 KB
Downloads

Text Preview

D7212 Control Communicator Security Systems Intrusion and Fire Features Eight programmable areas each perimeter interior partition master associate and area operation Real time clock test timer and to 1000 event memory log date time event ID and User ID Battery charging circuit and supervision AC power Automatic reset circuit On board CPU watchdog buzzer and diagnostic Lightning and EMI protection Power limited external circuits Built in digital communicator with line monitor loop or start Multiple telephone numbers and duplicate paths with and alternate destinations All Reports within each routing are programmable Optional dual phone line monitors 2 phone lines Automatic test and status Time windows for arming and report suppression Programmable answering work around for remote on shared phone Outputs 12 VDC 2 Amp alarm power 1.4 Amp Aux power 4 alarm output patterns Automatic bell test Programmable bell shut off timer 67 programmable outputs One parallel printer Response Eight on board detection points to 67 off board points for a of 75 points 31 custom point responses fire supervisory Selectable loop response time Fire Alarm verification Fire inspector local test Watch mode Scheduled events Skeds arm bypass and unbypass control relays and authority levels Interface Supervise up to 8 command up to 32 non super command centers can be Custom command center text Full function List including up to Custom Functions 99 users each with authority by and 16 character name 14 custom authority levels user authority to add and delete disarm bypass initiate system tests and Adjustable brightness loudness command center display P N 34041C 10 97 Specification Sheet 1997 Radionics Inc Description Radionics D7212 Control Communicator pro an integrated solution to Security and Fire System applications D7212 is a central control panel capable of alarm points for intruder or fire alarms operating user command centers and other The D7212 includes a built in digital commu which reports events to selected destinations programmable routes With programming and modules the D7212 offers flexibility and features rarely found in other security systems Configurations programming offers you a wide selection of system configurations Each area is as to one of up to eight account numbers to annunciation control and reporting functions Interface centers provide on premises point and status annunciation The D7212 provides a selectable user interface so you can customize center displays and simplify operation by menu items and functions and by only those menu items that are appropriate to area Function List can help the new user to become with the features of the control panel You the Function List for features and Custom that can be viewed at each command Functions allow users to perform complex with a few keystrokes Up to 4 Custom can be programmed each identified by 16 of custom text You can program the panel functions containing up to 32 keystrokes each D1255 Command Center D1256 Fire Command and D1257 Fire Annunciator use a 16 charac English language display to show system status status custom text and point status custom The D720 LED Command Center provides functions and annunciation for up to 8 in a single area Any combination of these centers can be used within the same area D7212 includes easy to remember command Familiar commands like Command 1 2 and Command 8 make the D7212 an transition for seasoned Radionics customers Passcodes D7212 system can accommodate up to 99 programmed user passcodes Passcodes 3 to 6 digits in length with no fixed digits user is assigned to one of 14 customized levels in each individual area You can the user to a different authority level for each and assign a time profile to control the user use user can be identified by a 16 character cus name When logged events associated with user are printed reported to the central station in Modem IIIa2 communications format or with Remote Account Manager RAM the associated with the user passcode is included and Fire Detection D7212 provides eight detection Add expansion interfaces and up to 67 points to provide up to 75 detection points points are individually programmable and may be to monitor all types of burglar alarm fire alarm supervision devices The D1255 D1256 and command centers show the status of indi points with custom text D7212 sorts reports by priority and is capable of reports to up to four Route Groups Each Group has a programmable Primary and destination The Radionics Modem IIIa2 format available with Radionics Receiver and the D7212 adds these reporting to name just a few Reports individual point numbers point text and event information Opening closing reports from up to 99 users with Identifies Opening Closing reports by area number Reports remote programming attempts Includes Diagnostic Reports Event Storage and Printing to 1000 events can be recorded in the D7212 built Logger memory All events local only and trans reports are automatically stored Each event entry contains the time date event description number point number and user ID command center function allows selected users to the event log from the command center The can be retrieved remotely using RAM print as they are stored in the D7212 event One D9131A Parallel Printer Interface can be to record events locally on a printer The can record opening and closing access Skeds or any combination of events The can supervise various printer status condi P N 34041C 10 97 Specification Sheet 1997 Radionics Inc Applications and Local Printer are ideally suited for the who would like to have a record of openings closings without having the extra communica cost Using Logger and the Remote Account you can suppress reports and then retrieve security system events periodically using one call rather than receiving several calls each the panel event log reaches the programmed of stored events the D7212 sends a report the D6500 receiver to remind the central station to events from the panel log with the Remote Manager Events Skeds Day of week or date of the year schedules Four holiday schedules of 365 days each Up to 64 scheduled events with 17 different Remotely programmable with User control from the command center D7212 internal clock and calendar help the operate individual scheduled events Skeds can program each Sked to perform a specific such as arm disarm relay control point etc Each Sked is programmed for a time either a day of the week schedule or a date of the schedule User can change the time for the Sked if the is programmed for local time editing Holiday can be used to enable or disable individual during the holiday periods Test the Fire Test Mode the D7212 suppresses reports the receiver so you can test initiating and indicating without transmitting alarms to the central When you put the D7212 in Fire Test Mode panel sends a report to the central station to the start of the test Test events then become only The command center shows how many are to be tested time a device initiates an alarm the pro point text displays at the command center automatic sensor reset feature of the Fire Test allows you to continue testing additional without time consuming trips to the command to manually reset sensors At the end of the

Related Files