Cerberus Pyrotronics GAD and RRD Remote Graphic And Relay Driver Modules 9361
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-gad-and-rrd-remote-graphic-and-relay-driver-modules-9361-4081579236.pdf |
---|---|
Type | |
Size | 1023.30 KB |
Downloads |
Text Preview
GAD and RRD Remote Graphic and Relay Driver AND ARCHITECT SPECIFICATIONS RRD Energizes Relays GAD Illuminates Graphic Annunciators Up to 24 Combined Module Capacity Header Connections for use with User LED Graphic Panel Listed FM CSFM and Approved Remote Graphic Driver and Relay Driver are modules can be used to illuminate graphic annunciators or relays The Remote Graphic Driver Module is GAD and the Remote Relay Driver Module is model modules have a header i e a male connector for a pin wire connector The wire connector from the is fastened to a user supplied LED graphic panel wire connector from the RRD is fastened to a user UL listed relay unit GAD and RRD modules can be connected anywhere the IXL network communication lines the Graphic Drivers GAD are connected to user graphic annunciators the GAD can support up to graphic annunciated points Both alarm and trouble can be annunciated with the use of the GAD used treat the Graphic Driver as a remote annuncia in power calculations with each module accommodat up to 8 points Remote Relay driver must include relay current in line loading calculations wires coming from both the GAD and RRD driver card not supervised Therefore if possible always mount GAD in the same cabinet as the graphic display or for RRD mount it in the same box as the relays and Architect Specifications Graphic drivers shall be a model GAD Remote drivers shall be a model RRD These driver modules be connected anywhere onto the IXL system network lines These modules shall have headers enable connection to user supplied LED graphic panels user supplied UL listed relay unit NUMBER RRD Wiring Diagram GAD Wiring Diagram Information Operating Characteristics Graphic Driver GAD Power Current VDC 2mA no LED on per Alarm LED per Trouble LED when ALL LED are on for Lamp Test Relay Driver RRD Power Current VDC 2mA no relays on per Alarm relay 50mA Trouble relay 800mA when relays are on as for Lamp the modules using their plastic mounting plates to convenient mounting surface such as a graphic panel housing Pyrotronics Ridgedale Ave Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1994 sheet dated 8 93