Cerberus Pyrotronics ILP ILPT-1 Intelligent Photoelectric Detector 6164
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-ilp-ilpt-1-intelligent-photoelectric-detector-6164-5491380672.pdf |
---|---|
Type | |
Size | 717.87 KB |
Downloads |
Text Preview
ILP Series Photoelectric Detectors for IXL MXL and XL3 Panels AND ARCHITECT SPECIFICATIONS ILPT 1 Motorola Microprocessor Based Design Technology Provides High Speed Fault System Detector Communications Supervision Protects Critical Detector Resistant to RFI EMI and Humidity Sensitivity Adjustment and Measurement Cleanable Photochamber Indicator LED Operation 135 Degree F Thermal Model ILPT 1 with SENSORLINK Model FPI 32 Field Program Verify Detector Perform Diagnostic Testing of Detectors Software Based Automatic Environmental available only when used with MXL Fully Programmable Relay Base and Audible Listed ULC Listed FM CSFM NYMEA and City of Chicago Approved Pyrotronics ILP 1 and ILPT 1 intelligent photoelec smoke detectors offer the fire and life safety industry the advanced method of detection programming and available today Additionally the ILP series provide an extremely high degree of resistance to EMI and humidity The ILP Series photoelectric detec utilizes a state of the art Motorola microprocessor with EEPROM The microprocessor provides the to operate the detector sophisticated detection checking and supervision algorithms ILP Series intelligent photoelectric detectors are with Cerberus Pyrotronics SensorLINK FPI 32 programmer tester The FPI 32 is a compact portable accessory which makes programming and detectors faster easier and more reliable than other The FPI 32 eliminates the need for cumbersome mechanical programming methods and reduces and service costs by electronically program addresses and functionally testing the ILP perfor before the detector is installed ILP Series photoelectric detectors are also compatible Cerberus Pyrotronics IXL MXL and XL3 control ILP Series detectors are Underwriters Laboratories ILP 1 and ILPT 1 are plug in two wire photoelectric compatible with Cerberus Pyrotronics IXL MXL XL3 systems Each ILP detector consists of a dust field cleanable photo chamber microprocessor electronic circuitry with plastic cover and base component packaging uses surface mount type NUMBER The entire electronic assembly is fully protected noise transients by shielding and is coated to resist and corrosion ILP 1 and ILPT 1 photoelectric detector utilizes a light diode LED and light sensing photodiode in a fixed array so that under normal conditions transmitted by the LED is directed away from the and scattered throughout the smoke chamber a controlled pattern The smoke chamber is designed to light dissipation and extraneous reflections from particles or other non smoke airborne contaminants in a way as to maintain stable consistent detector ILP 1 and ILPT 1 detector microprocessor uses an EEPROM to store the detector address and other operating parameters which include an assigned value for alarm and trouble thresholds microprocessor software employs sophisticated algorithms to identify and disregard false alarms by radio frequency RFI and electromagnetic EMI and also validates all trouble conditions before or reporting to the control panel Communica within the detector itself and also between the ILP 1 ILPT 1 detectors and the control panel or the FPI 32 accessory are supervised and safeguarded disruption by reliable microprocessor based error routines Additionally the microprocessor super all EEPROM memory locations and provides a high of EEPROM failure fault tolerance IXL or MXL applications an ILP series detector deter it operating status to be normal in alarm or in depending on the difference between the alarm value stored in the detector memory and the latest analog measurement The detector then changes in its status to the MXL or IXL panel In addition MXL panels will periodically the value of the detector analog signal in order to if those values indicate excessive dust buildup in photo chamber if so the MXL will indicate that the detector requires maintenance For XL3 control applications the detector operating status is to be normal in alarm or in trouble depending the difference between the alarm threshold values in memory at the XL3 panel and the analog value of transmitted by the detector and evaluated at the panel an ILP series detector alarm condition is confirmed the control panel the detector LED flashes and flashing until the system is reset at the control Also any user defined system alarm function or by event functions are activated Each ILP series is capable of operating one series remote alarm or one auxiliary relay or one audible base sensitivity calibration and identification are supervised by the control panel Detector can be changed from the control panel SensorLINK FPI 32 Program Test accessory is used to and verify the detector address The technician the accessory program mode to enter the desired The FPI 32 will then automatically set and verify address and test the detector The FPI 32 operates on power or rechargeable batteries providing the flexibility convenience to program and test detectors anywhere in the test mode the FPI 32 will perform a series of tests on the ILP detectors without altering the allowing technicians to determine if the detector is properly or not ILP series detectors may be installed on the same MXL XL3 circuit with ID 60 series detectors MSI series manual TRI series interfaces ICP output control devices or CZM series conventional zone modules The ILP series may also be installed on the same XL3 circuit X series detectors manual boxes or interface modules series detectors may be installed on the same IXL circuit with other series detectors manual boxes TRI interfaces ILP series detectors can be cleaned in the field as by simply removing first the detector cover then photo chamber cover and cleaning the interior surfaces the photo chamber with a clean soft cloth or brush ILPT 1 is a photoelectric detector with a restorable sensor An alarm will be initiated when the tempera around the detector thermal sensor reaches 135 Fahrenheit 57 or when sufficient smoke enters photoelectric chamber series detectors are also designed for use with Cerberus AD 3ILP air duct housings for air duct applica If a relay is desired use a DA X3SR module with the housing ILP series detectors use the Cerberus Pyrotronics low surface mounting detector bases Detector base DB 3S mounts to a 4 inch octagonal square or gang electrical box Relay base model DB X3RS to a 4 inch square deep electrical box Audible model ADBI 60 mounts to a 4 inch square deep box When a 4 inch square or 4 inch square deep box is used an optional trim ring is available RA ADB The DB 3S DB X3RS and ADBI 60 bases screw clamp terminals for all electrical connections and contacts for increased reliability These bases a provision for an optional concealed locking model DB LK to prevent unauthorized removal the detector head ILP series photoelectric detectors are approved for within the U L specified temperature range of 0 38 Data Data of the ILP series of photoelectric detectors a two wire circuit of 18 AWG thermoplastic fixture enclosed in conduit or 18 AWG limited energy cable without conduit if permitted by local build codes Field wiring should conform to local and National Codes and to the control panel wiring specifica is permitted only for Style 4 Class B wiring series photoelectric detectors can be applied within the 30 foot center spacing 900 sq ft areas as in NFPA 72 This applications guideline is based ideal conditions specifically smooth ceiling surfaces air movement and no physical obstructions potential fire sources and the detector Do not detectors in close proximity to ventilation or heating air conditioning outlets Exposed joists or beamed may also affect safe spacing limitations for detec Should questions arise regar