Cerberus Pyrotronics IXL Intermediate XL Member of InteLINK Family 9350
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-ixl-intermediate-xl-member-of-intelink-family-9350-8196402735.pdf |
---|---|
Type | |
Size | 1003.90 KB |
Downloads |
Text Preview
IXL Intermediate XL Member of the InteLINK Family AND ARCHITECT SPECIFICATIONS NFPA Standard 72 Style 6 Class A or Style 4 Class B Line Circuits NFPA Standard 72 Style Z Class A or Style Y Class B Appliance Circuits Microprocessor Technology Fully Field Programmable Menu Driven Programming Software Interactive Panel Keypad with Guided Sequential Control of Alarm Trouble Supervisory Functions by Point or Zone Supports all Series Intelligent Analog Input Devices User Selectable Series Smoke Detector Sensitivity Settings Remote UL Sensitivity Test for Series Smoke Detectors Alarm Event and Trouble Status Buffers History Log Self Diagnosis Power Limited Password Access Protection Positive Alarm Sequence Alarm Verification 24 Hour Trouble Reminder Signal Silence Inhibit and Time Limit Cutout One Person Test and Print Out Two Supervised Indicating Appliance Circuits Rated At Each VAC Jumper Programmable Master Box Line Reversal Circuit Four Form C Relays Rated At 1A 30 VDC or 200mA Dual Mode Battery Charger Degrade Operation Mode Full Array of Optional Modules and Devices Circuitry Does Not Require Shielded Cable Listed ULC Listed FM CSFM NYMEA Approved IXL part of the Cerberus Pyrotronics family of fire life safety equipment Ideal for buildings of size the IXL provides a full array of standard optional features IXL is fully supervised power limited and fully field control panel The standard control panel two network communication lines these lines are by NFPA72 as signaling line circuits This can be expanded to monitor up to four network lines network communication line consists of one data two power lines and one earth return line The data power lines are supervised for open circuit short and earth faults NUMBER network communication lines can support a variety of modules and devices for maximum system These addressable modules and devices include to 256 addressable input devices This limit can be by a combination of any of the following to 256 conventional zone modules to 4 Series control modules to 240 Series devices detectors manual TRI interfaces 224 addressable control element relay output 24 addressable LED annunciators or graphic or 16 high visibility LCD alphanumeric displays or interfaces interfaces 16 remote panel control modules 4 generic switch control modules system operator can select one of four smoke sensitiv settings for a specific Series smoke detector in on an ICon circuit In addition the IXL displays at panel a specific Series smoke detec tor analog value This feature permits the user to perform a listed smoke detector sensitivity test system architecture allows for T tapping of the NFPA 72 Style 4 Class B signaling the circuits line circuits can be configured for either NFPA 72 Style 6 Class A or NFPA Standard 72 Style 4 B operation of the major benefits of the IXL system is that it is fully programmable Utilizing the IBM compatible computer the panel interactive keypad the IXL can be custom to meet specific installation requirements interactive keypad allows you to perform basic system in the normal program and test modes You are through the system operation by LED that flash in to indicate available operation choices The IXL also password access protection for the use of the panel additional security is necessary These features installation reconfig uration and maintenance simple and Architect Specifications your nearest Cerberus Pyrotronics sales outlet for copy of the IXL Specification Guide IXL consists of the main control panel and enclosure the IXL system It contains the intelligence for the All data is processed and transmitted to other in the system via the network communication IXL also has two notification appliance alarm signal rated at 2 Amp Each either Style Z Class A or Y Class B The IXL municipal tie circuit is jumper for master box or line reversal circuit There is a built in battery charger with a 40 AH battery capac The IXL has four Form C contacts rated at 1A at 30 or 200 mA at 120 VAC The relays are for alarm supervisory and degrade mode operations Control Panel Keypad and Display IXL keypad and display contains seven LEDs Green Yellow These LEDs are indicators that Alarm Trouble Supervisory or Bell Silence Service CPU Failure are also seven keys that are function keys with indicating LEDs For the normal program test operations the user will use the function keys to selections and to receive information from the These function keys are Reset F2 Day F3 Test Program Enter data display has four 4 red digits Each digit illumi to indicate a number or a letter IXL has three modes of operation normal program test Each mode enables the user and the system to monitor and control the protected environment the operating mode any condition such as normal power on alarm trouble or supervisory condi will be annunciated at the panel During the normal with no events or abnormal conditions occurring the green LED will remain lit program and test modes unlike the operating mode be used only after entering the user password tests can be performed by selecting the key various programming functions can be completed by the key The following are the various the Test Mode Test main board relays Test initiating devices with without audibles Test control elements Test alphanumeric annunciators printers Test panel lamps and remote lamps Access and print system history log Access and print system history log Test remote annunciator lamps Test generic switch control modules Test remote control modules Locate a initiating device Display detector sensitivity voltage Adjust detector sensitivity level the Program Mode Bypass enable main relays Bypass enable initiating devices Bypass enable control elements Bypass enable alphanumeric printers Enable all bypassed main board relays Enable all bypassed initiating devices Enable all bypassed control elements Enable all bypassed alphanumerics printers Program initiating devices Program control elements Add the IXL EXP module Program remote drivers Annunciator Graphic Relay Program generic switch control modules Program remote control modules Expansion Module IXL EXP IXL system IXL EXP expansion card module gives IXL the additional capability of accommodating op addressable modules and devices IXL EXP is equipped with tow addressable network signaling line circuit connections which a mximum 5 Amp Each This module maximum 4 Class B wire run including T tap runs to the last device is 2000 feet Series Control Module ICon ICon Series control module provides the commu interface between the IXL system and the Pyrotronics Series intelligent devices These Series devices include all models of the ID 60 Series the universal base the MSI manual stations and interfaces The ICon module can be placed anywhere the IXL network communication lines maximum of four ICon Series control modules can be with the IXL Each ICon must be assigned on of the available input device addresses Each ICon module support up to sixty addressable intelligent series the ICon is used with the ID 60 intelligent ion or detectors the user via the IXL keypad can the detectors sensitivity to one of four levels low normal or high In addition by using the IXL Test mode a user can retrieve an intelligent ion or detectors actual sensitivity voltage reading This allows the user to remotely test the detector at the control panel per UL requirements with all Cerberus Pyrotronics Series intelligent these devices can be programmed and tested using the compact menu driven programmer tester The SensorLINK also the user to test the detector sensitivity Zone Interface Module CZI conventional zone interfaces known as the CZI Seris