Cerberus Pyrotronics LIM-1 Loop Isolator Module 5040

File Preview
File Preview
Click below to download for free

File Data

Name cerberus-pyrotronics-lim-1-loop-isolator-module-5040-5091742386.pdf
Type PDF
Size 727.73 KB
Downloads

Text Preview

ENGINEER AND ARCHITECT SPECIFICATIONS AND ARCHITECT SPECIFICATIONS Isolator Module Isolator Module Short Circuit Isolation Used on MXL Intelligent Device Circuits Increased Fault Tolerance Style 4 or Style 6 Up to 12 Per ALD Circuit Max Requires no Programming Does Not Occupy a Device Address Mounts in Either 411 16 Square or 2 Gang Box Local LED Indicator Cover Plate Included ULC Listed NYMEA and CSFM LIM 1 loop isolator module provides short circuit on MXL intelligent device circuits ALD a short is detected by the LIM 1 it isolates the segment of the circuit allowing the remaining to continue operation The LIM 1 is self restor automatically reconnecting to circuit segment when fault is removed LIM 1 also includes a yellow LED which illuminates indicate that the device has been activated The LIM mounts in either a 411 16 square 3 deep or 2 gang box and is supplied with a cover plate with an for the LED can be wired in either a Style 4 or Style 6 configura LIM 1 does not occupy a device address on the circuit and requires no programming Up to twelve may be installed on each ALD circuit and Architect Specifications and Architect Specifications circuit isolation shall be provided for all intelligent circuits The isolator shall mount in a 411 16 3 deep or single gang electrical box and shall a yellow LED to indicate activation It shall also a cover plate with an opening for the LED isolator model LIM 1 shall be a self restoring device no programming and shall not occupy an on the intelligent device circuit It shall be of being configured in either Style 4 or Style 6 Ratings Ratings Power Line Resistance LIM 1s ohms VDC 500 mA max Information Information Number NUMBER Wiring Diagram Wiring Diagram B Installation B Installation Diagrams Diagrams Gang Box Inches Deep Inch Square Box Inches Deep for Class B Installation wiring must comply with national and local codes not install more than 20 devices on a single LIM 1 Minimum wire gauge is 18 AWG total wire resistance both wires between LIM 1s exceed 20 ohms not install more than 12 LIM 1s per ALD loop circuits are supervised to the MXL MXLV Manual P N 315 092036 for the of compatible devices Wiring Diagram Wiring Diagram A Installation Single Loop A Installation Single Loop Installation a standard 31 2 inch deep double gang electrical or a 411 16 inch square electrical box that is 21 8 deep the field wiring Press the LIM 1 into the box and the module plate to the box the module front plate with the plate supplied and with screws supplied for Class A Installation Single Loop wiring must comply with national and local codes not install more than 20 devices on a single LIM 1 Minimum wire gauge is 18 AWG total wire resistance both wires between LIM 1s exceed 20 ohms not install more than 12 LIM 1s per ALD loop circuits are supervised to the MXL MXLV Manual P N 315 092036 for the of compatible devices Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 www cerbpyro com in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 8 96

Related Files