Cerberus Pyrotronics MID-16 Programmable Input Driver 5017
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-mid-16-programmable-input-driver-5017-3140679285.pdf |
---|---|
Type | |
Size | 678.39 KB |
Downloads |
Text Preview
ENGINEER AND ARCHITECT SPECIFICATIONS Input Driver 16 Individually Programmable Inputs Monitoring of Switches and Contacts Supervises Lamps Programmable Alarm Trouble Status and Security Identity Screw Terminals or Connector Interface Up to 128 Inputs from one MOI 7 Listed MID 16 is an input module used in conjunction with the as a part of the Cerberus Pyrotronics MXL system to eight MID 16 can be connected to a single MOI 7 with eight MOD 16 output driver modules Each MID provides a non supervised input that can monitor devices Each individual MID 16 input can be used as a part of MXL custom programming These inputs can be individually set for either alarm trouble security or status usage They can be configured to provide supervision for lamps driven MOD 16 outputs Screw terminals and connectors are on the MID 16 modules for interface to monitored The MID 16 occupies one System 3 type module and Architect Specifica and Architect Specifica inputs shall be provided by the Cerberus model MID 16 input module The MID 16 shall used in conjunction with the MOI 7 and optionally the as a part of the MXL system Each MID 16 shall 16 non supervised inputs for monitoring contact devices Up to eight MID 16 and eight MOD 16 may be connected to a single MOI 7 providing a of 256 I O points individual MID 16 input shall be capable of being either alarm supervisory trouble security or identity and shall be capable of being fully incorpo into the system logic MID 16 shall be Underwriters Laboratories Inc listed Information Information Power VDC max Ratings Voltage Range Impedance Current equipment is approved for operation over the tem range of 0 and 49 VDC ohms max NUMBER Connection Connection 18 AWG minimum for all input connections 14 AWG minimum for supply connections TB 1 9 and TB 2 9 and 10 All wiring must be in accordance with NEC 760 All wiring must meet local codes and satisfy the having jurisdiction over the installation All wiring to MID 16 is unsupervised Any wiring the enclosure must be in rigid conduit and not leave the room For additional information see MOI 7 module P N 315 090829 A maximum of 8 MID 16 can be used with the MOI 7 P1 is connected in parallel with TB1 P2 is connected in parallel with TB2 Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 www cerbpyro com in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 9 95