ENGINEER AND ARCHITECT SPECIFICATIONS Output Driver Open Collector Current Sink 16 Outputs Sequenced or Simultaneous Lamp Test Programmable Operates LED or Incandescent Lamps Relay Driver Listed ULC Listed CSFM NYMEA and City of Chicago MOD 16 is an output driver module used in conjunc with the MOI 7 as a part of the Cerberus Pyrotronics system Up to eight 8 MOD 16s can be connected an MOI 7 interface module Each MOD 16 provides 16 open collector current sinking outputs rated at VDC 50mA MOD 16 outputs are programmable the MXL custom software These outputs can either LEDs or 24 VDC incandescent lamps The outputs can be lamp tested from either the MOI 7 the MXL When the lamp test is activated all outputs be pulsed rapidly in sequence or lit simultaneously MOD 16 outputs can also be used to activate relays as the SR 35 MOD 16 occupies one System 3 type module space MOD 16s connect together using a ribbon cable equipment is approved for operation over the tem range of 0 and 49 and Architect Specifications open collector outputs shall be provided by Cerberus Pyrotronics model MOD 16 output driver MOD 16 shall be used in conjunction with the MOI 7 interface as part of the MXL system Each MOD 16 provide sixteen 16 open collector current sinking rated at 24 VDC 50mA Each output shall be fully via the MXL custom software MOD 16 outputs shall be capable of being lamp either from a local input to the MOI 1 or from the When in lamp test mode all LEDs shall be pulsed in sequence or turned on simultaneously This shall selectable in system programming MOD 16 shall be capable of activating compatible such as the SR 35 to eight MOD 16s may be connected to each MOI 7 MOD 16 shall occupy one System 3 type module MOD 16s shall be connected together via a ribbon MOD 16 shall be Underwriters Laboratories Inc Information voltage current 2mA Current sink current each output peak max max NUMBER Data 18 AWG minimum for LED and 24V connections 14 AWG minimum for supply connec TB1 9 and 10 TB2 9 and 10 All wiring must be in accordance with 760 All wiring must conform to local of the authority having over the installation All wiring to MOD 16 is unsupervised must not leave enclosure For additional information see MOI 7 instructions P N 315 092799 A maximum of 8 MOD 16s can be with the MOI 1 When using SR 35 refer to Table 1 Both TB1 9 or 10 and TB2 9 or 10 be connected to the common the power supply 1 1 The use of other than Cerberus Pyrotronics detectors and bases with Pyrotronics control equipment will be considered a misapplication of Pyrotronics equipment and as such void all warranties either expressed implied with regards to loss damage liabilities and or service problems Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 9 95