Cerberus Pyrotronics PAD-2 Auxiliary Power Supply NAC Extender 3352

File Preview
File Preview
Click below to download for free

Text Preview

PAD 2 Power Supply NAC Extender AND ARCHITECT SPECIFICATIONS 6 amps of Notification Appliance Power Advanced Microprocessor Control 24 VDC Regulated Output Voltage Four Power Limited Notification Outputs Synchronized ANSI Temporal Pattern Class Selectable Gound Fault Detection Battery Supervision 3 Amp Auxiliary Power Output Trouble Contact for Monitoring Listed Model PAD 2 is a notification circuit expander with a auxiliary power output It is listed by Underwriters for use with Cerberus Pyrotronics fire alarm panels This power source is designed to provide extra power required in buildings conforming to the with Disabilities Act PAD 2 provides 6 amps of regulated 24 VDC power multiple uses All 6 amps can be directed to 4 Appliance Circuits NAC Each is rated at amps and is power limited Either 1 or 2 inputs can the four outputs These outputs are compatible all Cerberus Pyrotronics 24 VDC notification appli PAD 2 also offers a 3 amp auxiliary output for other portions of your fire alarm system This is power limited and regulated at 24 VDC When this output the total power available from the will not exceed 6 amps trouble contact is provided for monitoring the PAD 2 a fire alarm panel It also allows for a contact input the user has the option of connecting it to a fire alarm panel existing notification oror controlling it with a TRI series device on fire systems PAD 2 offers battery supervision and management is required of fire alarm system components Ground are transmitted as are any other trouble condi Trouble conditions not only change the state of trouble contact in the unit they also break the circuit input to create a trouble signal in the alarm control product is packaged in its own sheet metal enclo with enough space to house the 7 amp hour set required for back up The enclosure is black displays the Cerberus Pyrotronics logo The PAD 2 listed by Underwriters Laboratories Inc or both PAD 2 signal inputs control the notification NUMBER depending on the specific configuration setup configurations for the PAD 2 are These 1 Outputs B Circuits 1 2 1 2 1 and 2 3 and 4 B Circuits B Circuits 1 2 3 and 4 B Circuits B Circuits 1 Outputs 1 2 and 3 4 Class A Circuit Pairs 1 2 1 2 3 4 A Circuit Pairs A Circuit Pairs A Circuit Pairs B Circuits 1 2 3 and 4 1 2 Model PAD 2 supervises a variety of functions Low AC power Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition an output a trouble condition occurs the PAD 2 creates a condition on the fire control signal circuits to it is connected It still maintains the ability to be by the fire control In addition the PAD 2 a Form trouble relay output as an alterna to using the notification circuit trouble Diagram Electrical Input Power Circuit 1 Ciruicts Class A or 4 Class B or Configuration Class A 2 Class B VAC 2 amps VDC 6 amps per Output Circuit to 27.3 VDC at 3.0 amps 4.7K ohm EOL resistor on each Class B circuit Class B or 2 Class A VDC AH to 120 x 16 x 3 of Inputs Configuration Voltage Range Charging Temp Lights Power On Trouble Fault Trouble 1 Trouble 2 Trouble 3 Trouble 4 Trouble Information Number Pyrotronics Ridgedale Ave Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1996 sheet dated 12 95

Related Files