Cerberus Pyrotronics PAL-1 Parallel Printer 5048
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-pal-1-parallel-printer-5048-4159283076.pdf |
---|---|
Type | |
Size | 1.11 MB |
Downloads |
Text Preview
ENGINEER AND ARCHITECT SPECIFICATIONS Printer Parallel Printer Supervised for Paper Out On Off Line On Paper Jam Connection MXL CXL MXL G MXL GT CXL G NCC High Speed 24 Pin Dot Matrix Wide Carriage Tractor or Friction Feed NFPA 72 Proprietary Listed PAL 1 is a UL listed parallel printer for use with the CXL MXL G MXL GT CXL G and NCC It provides hard copy record of all system events It also allows of system maintenance and diagnostic reports used with the MXL the PAL 1 requires connection PIM 2 and PIM 1 When used with CXL the PIM 2 is to connect the PAL 1 to the CXL printer port the CXC 2 module printer is a 24 pin wide carriage dot matrix with type interface It is supervised for AC power line paper out paper jam and connection to FACP used in an NFPA 72 proprietary configuration a listed UPS must be supplied and Architect Specifications system shall provide a UL listed parallel printer The shall be high speed wide carriage with 24 pins matrix type The printer shall support the use of traction feed or friction feed paper It shall be fully for proper operation including On Off Line Jam Paper Out Power On and wiring between and fire alarm system PAL 1 shall be capable of being used with either the Pyrotronics MXL or CXL systems It shall also used with the MXL G MXL GT CXL G SCXL and systems used with the MXL the PAL 1 shall be connected the PIM 1 and PIM 2 modules Power to the PAL 1 be provided by a UL listed UPS in all NFPA 72 systems NUMBER Wiring Diagram Maximum cable distance from PIM 1 to PIM 2 cable is 25 The two modules must be in the same room maximum distance from the PIM 2 to the parallel is 6 feet The two modules must be in the same power PWR is connected to the 5 VDC 600mA supplied with PIM 2 The transformer requires VAC 60 Hz 0.5A max NFPA 72 Local Auxiliary and Remote Station config connect the output of the PIM 2 to any UL listed Centronics parallel printer parallel printer must support the EPSON FX com set PIM 2 input and output connectors are DB 25 female RESET on the PIM 2 causes the unit to read the settings The status LED is lit when the unit is Do not use the COPY button NFPA Proprietary and UL 1076 configurations use printer Model PAL 1 a UL listed for fire Centronics printer parallel printer is supervised for AC on off line paper paper jam and connection to the PIM 2 The PIM 2 is supervised for power connection to the and connection to the PIM 1 Wiring Diagram Maximum distance from PIM 2 to parallel printer is 6 feet modules must be in the same room PIM 2 power PWR to the 5 VDC 600mA supplied with PIM 2 The transformer 120 VAC 60 Hz 0.5A max input and output connectors are DB 25 female RESET on the PIM 2 causes the unit to read the settings The status LED is lit when the unit is Do not use the COPY button revision 8.0 or higher of CXL firmware to support this is supervised for AC on off line paper out paper and connection to PIM 2 is supervised for power connection to printer and TO NOTES 6 AND 7 IT IS NOT SUPERVISED DATA INTEGRITY BETWEEN AND THE PRINTER IN UL LISTED ELECTRICAL BOX Information Number Parallel Printer Instructions Pyrotronics Ridgedale Ave Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 4 94