Cerberus Pyrotronics PIM-1 Interface Module 5015
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-pim-1-interface-module-5015-1039254867.pdf |
---|---|
Type | |
Size | 732.49 KB |
Downloads |
Text Preview
ENGINEER AND ARCHITECT SPECIFICATIONS Interface Module Interface to Remote Printers Interface to Serial Printers Video Display MXL VDT Parallel Printers PAL 1 PIM 2 MXL Color Graphics System and MXL Color Terminals MXL GT RS 232C Communication Terminal Block Connector Bi Directional Listed ULC Listed FM CSFM NYMEA and City of Chicago Approved PIM 1 is an MXL option module which provides an RS 232C port for connection to peripheral devices as serial printers CRTs and VDTs The PIM 1 mounts standoffs in the MXL enclosure It connects to the or MMB 2 and provides a screw terminal block for wiring PIM 1 provides a supervised connection to the PIM 2 printer module to allow MXL to operate with any listed printer such as PAL 1 PIM 1 also provides full control and annunciation of the MXL Color System MXL G and Color Terminal Systems equipment is approved for operation over the tempera range of 0 to 49 and Architect Specifications and Architect Specifications between the MXL system and remote periph devices such as printers CRTs and VDTs shall be by the PIM 1 module The PIM 1 shall mount in MXL enclosure and provide a standard screw terminal for field wiring The interface shall be RS 232C and ground isolation between the MXL and the periph devices Data Data Ratings for RS 232C 12 VDC 5mA cable length 25 feet Data Data on four standoffs in the MXL enclosure MBR 2 For that use the MKB 4 keyboard the PIM 1 on the back of the MKB 4 can also mount in the RCC 1 Remote Display and to provide remote printers VDTs or Graphics NUMBER Diagram Diagram to jumper G1 place if the printer is jumper G1 if System has unsupervised CONNECTIONS This table refers to whether or not the wiring connections are supervised table does not refer to the type of printer used in the System Terminals TB1 8 and 9 are connected together on the PIM 1 The busy signal from the printer prevents the loss of characters if the printer falls Refer to the printer manual for the proper pin usually 11 TB 1 3 or 20 Information Information Number Interface Module Instructions Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 www cerbpyro com in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 9 95