Cerberus Pyrotronics PS-35 System 3 Power Supply 3061
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-ps-35-system-3-power-supply-3061-6071254389.pdf |
---|---|
Type | |
Size | 1008.34 KB |
Downloads |
Text Preview
ENGINEER AND ARCHITECT SPECIFICATIONS 3 Power Supply Multiple Usage Deadfront Construction Modularized ULC Listed FM NYMEA and of Chicago Approved Cerberus Pyrotronics power supply model PS 35 is a transformer and bridge rectifier designed for with control panel model CP 35 or to provide addi DC power for notification appliances units which are modularized for System 3 enclosure are of deadfront construction and contain a strip circuit breaker with a reset switch on the AC protection fuses on the DC outputs and a receptacle jumper plug connection directly into the control panel CP 35 PS 35 occupies three module positions within the 3 enclosure model PS 35 provides a rectified full wave 24 VDC from an input supply of 120 VAC 50 60 Hz The consists of a main power phase and a trouble phase separately fused and a common neutral 24 volt full wave output is rated at 10 Amp DC full When the PS 35 is used to power the control panel the second output terminals 5 6 rated at 24 1.5 Amp is used to power modules internally and wired within the control unit enclosure protection is provided across both input phases as as the DC output When an additional PS 35 power supply is used for notification appliance power in a CP 35 con system with emergency power a transfer module is required to supply emergency power to the appliance circuit and Architect Specifications power supply for the alarm system shall be a Pyrotronics model PS 35 The unit shall be Laboratories Inc Listed unit shall provide a full wave of rectified 24 VDC output at 10 Amp full load The PS 35 shall be capable of 100 detection zones 49 ZU 35 zone modules 4 fully loaded alarm extender modules model AE simultaneously rated output which shall be completely fused shall be at a plug receptacle A second output terminals 6 rated at 24 VDC 1.5 Amp is used to power internally housed and wired within the control unit power supply shall be of deadfront construction and in a steel enclosure compatible with the modular alarm system Externally mounted 120 VAC 24 VDC shall not meet the intent of this specification NUMBER Information Requirement VAC 50 60 Hz wire 3.5A max model PS 35 plus the CP 35 control panel occupy normally taken by eight modules The power supply the CP 35 must be mounted in the upper right hand of a System 3 enclosure This should be consid when sizing the enclosure power supplies if required are mounted to the modules to be powered by them Wiring Information No Supply lb 8.3 The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics equipment will be considered a misappli cation of Cerberus equipment and as such void all warranties either expressed or implied with regards to loss damage liabilities and or service problems Pyrotronics Ridgedale Ave Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 8 94