Cerberus Pyrotronics PSR-1 Remote Power Supply 5010

File Preview
File Preview
Click below to download for free

File Data

Name cerberus-pyrotronics-psr-1-remote-power-supply-5010-3658247091.pdf
Type PDF
Size 1.13 MB
Downloads

Text Preview

ENGINEER AND ARCHITECT SPECIFICATIONS Power Supply 24VDC Power Supply 5VDC Regulated 6 Amp or 12 Amp Output Power Options Microprocessor Controlled Status Indicator Lights Common Alarm Relay Common Trouble Relay Degrade Mode 19 Rack Mount Capability 2 Amp 24VDC Class A Power Output Power Limited Auxiliary Power Output Listed ULC Listed CSFM NYMEA FM and City of Chicago PSR 1 is a microprocessor controlled remote power and battery charger for use with the Cerberus MXL It operates in conjunction with either an or MPS 12 to provide 6 or 12 Amps of power for with various MXL modules When used with a NET 4 or plug in communication module the PSR 1 a part of the MXL RS 485 network It acts as an between remote option modules and the MXL PSR 1 can be mounted in the MBR backbox and is an part of the MXLR or MXLRV remote units It can be mounted in a graphic annunciator panel and used power an MOI MOD annunciator driver set The PSR 1 also be used to power a remote MKB 2 module When with an MOI 7 a NET board is not required Interface the network is provided by the MOI 7 PSR 1 provides LED status indicators for Power On Power On 24VDC Aux Power On Battery Trouble Power Trouble Ground Fault Transmit Enable Trouble and Common Alarm PSR 1 always requires an MPS 6 or MPS 12 PSR 1 provides a common alarm and a common relay When connected to a MOM 2 or MOM 4 containing option modules data is transferred to from the MXL through the PSR 1 If the MXL main fails or network communication is lost the PSR will continue to receive a common alarm or common signal from modules in the MOM 2 or MOM 4 which it is connected When an alarm is received during operation it can activate local notification appli circuits are provided for interface to the MPS 6 or and MOI 7 TSP 40 and a MOM 2 or MOM 4 on board battery charger can charge up to 55 Amp batteries Any PSR 1 can be interrogated by the Battery voltage charge current DC load and AC can be viewed on the MKB display PSR 1 provides two 24VDC outputs a 2 Amp output is to power MXL remote intelligent modules such as and ICPs This output can be wired in a Class A configuration When wired this way a transfer relay supply power to these devices even during a single in the circuit This output is power limited per NEC and is supervised The other 24VDC output is used to MXL option modules PSR 1 is UL ULC listed and NYMEA FM CSFM This equipment is approved for operation over temperature range of 0 to 49 and Architect Specifications MXLR units shall be powered by a PSR 1 remote supply network communication module The PSR 1 be used with an MPS 6 or an MPS 12 The MPS 6 NUMBER MPS 12 each consists of a transformer bridge line filter and resettable circuit breaker The PSR 1 be capable of operating with a NET 4 or NET 7 7M communication module When used with a NET module the PSR 1 shall become a part of the MXL network Any MXL option module which is con to the PSR 1 will be capable of full bi directional communication with the main MMB PSR 1 shall provide 24VDC and 5VDC power to MXL modules Connectors shall be supplied to interface PSR 1 with compatible MXL option modules PSR 1 shall be capable of providing power to the output interface module and MOD 16 output driver for use with LED or lamp type annunciators or for Programmable Input Zones PSR 1 shall provide one power limited Class A auxil power output rated at 24VDC 2 Amp and one 24VDC limited output The Class A power output shall capable of being wired in a Class A configuration able supply power to its connected devices even during a open in the wiring When wired in a Class A configu power circuit wiring shall be fully supervised and fault shall be indicated at the PSR 1 as well as the main unit Power limiting shall be provided by a self thermal device Fuses shall not be used to supply limiting degrade alarm relay degrade trouble relay and on status LED shall be provided by the PSR 1 They be capable of operation in the event of MXL main failure or loss of network communication LED shall indicate Power On 5VDC Aux Power 24VDC Aux Power On Battery Trouble CZM 1 Power Ground Fault Transmit Enable Common Trouble Common Alarm PSR 1 battery charger portion shall be microprocessor and capable of charging sealed lead acid sized up to 55 Amp hours Battery voltage current DC load and AC mains voltage shall be of being queried and displayed at the MXL PSR 1 shall be capable of being 19 rack mounted Power Supply The use of other than Cerberus detectors and bases with Pyrotronics control equipment be considered a misapplication of Pyrotronics equipment and as void all warranties either expressed implied with regards to loss damage and or service problems Plate Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 6 96

Related Files