Cerberus Pyrotronics RTA-38 System 3 Remote Indicator Unit 3069

File Preview
File Preview
Click below to download for free

Text Preview

RTA 38 3 Remote Indicator Unit AND ARCHITECT SPECIFICATIONS Alarm Indicator Trouble Indicator Trouble Silence Switch Key Operated Alarm Switch ULC Listed CSFM and Approved model RTA 38 can be used with System 3 fire alarm for remote system indication Both alarm and conditions are annunciated visually and audibally local trouble signal can be silenced with a switch The switch for the alarm condition is key operated RTA 38 is listed by Underwriters Laboratories Inc and of Canada It is also approved by Factory Mutual the of California and the City of New York for use with 3 Information No No NUMBER Diagram Spaces 375 3.375 23 24 25a 25b 26 27 28 30 31 23 24 25a 25b 26 27 28 30 31 Unit Used 23 24 25 26 28 31 Up to Two 2 RTA 38 Units may be used When a RTA 38 is used remove jumper between terminals 25 and 26 of the CP 35 When a second RTA 38 is used remove jumper between terminals 25B and 26 of the first RTA 38 22 thru 26 VDC 100mA 27 28 VDC 28mA 30 31 VDC 2mA Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 www cerbpyro com in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 Issue