Cerberus Pyrotronics S-2406 Infrared Flame Detector 6150
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-s-2406-infrared-flame-detector-6150-6270514893.pdf |
---|---|
Type | |
Size | 550.77 KB |
Downloads |
Text Preview
Model S 2406 Infrared Flame Detector AND ARCHITECT SPECIFICATIONS Dual Sensors Discriminate Between Flames and Sources of Four Stage Sensitivity Selection a Very Sensitive Setting Wide Temperature Range of 13 158 Cerberus Pryotronics Selective Dual Sensor Infrared Detector Model S 2406 has been developed to the strictest requirements for reliability response and durability over a wide range of environ The four stage sensitivity selection includes a very sensitivity setting which will respond to a one square gasoline fire at a distance of 75 feet The housing is waterproof and immune to corrosion and salt spray Electronics are encapsulated and are protected behind scratch proof sapphire Operation is unaffected by high frequency and all elements are highly resistant to the S 2406 dual element infrared detector has designed to perform under severe environmental there are four user selectable sensitivity and dual element discrimination You can expect performance simplified installation and minimal of maintenance from this design S 2406 detector has two pyro electric sensors which sensitive in two different light wave lengths The first reacts to the infrared energy in the spectral range 4.1 to 4.7 m m which is emitted by heated carbon produced by combustion of materials containing such as wood alcohol oil products plastics The sensor reacts to infrared energy in the spectral 5 to 6 m m emitted by typical interference sources as artificial light heaters and hot vibrating surfaces having a typical flame flicker frequency from 2 to are amplified and checked for amplitude and phase IR energy is emitted by flames the signal amplitude the first sensor is larger than that from the second and an alarm is triggered If however the infrared is emitted by an interference source like a hot surface the signal from the second sensor will be same or larger and an alarm is not triggered flexibility in project application the sensitivity and integration time can each be set in two levels by small built in switch S 2406 has been designed for detecting fires where development of flames can be expected as with flammable liquids and gases The detector reacts all burning materials which contain carbon In addition detector has two pyro electric sensors and a sophisti electronic circuit which gives the detector immunity interference sources The S 2406 is therefore suitable applications even in extreme environments NUMBER infrared flame detector cannot be used for applica with phosphor sodium magnesium or hydrogen and Architect Specifications infrared flame detector shall be a Cerberus Pyrotronics S 2406 The infrared flame detector model S 2406 have a four stage sensitivity selection The infrared detector shall have dual sensors for the purpose of between infrared energy in the characteristic dioxide spectral range 4.1 to 4.7 m M and other energy typically emitted by interference sources in 5 to 6 m M spectral range The detector housing must impact resistant waterproof and immune to corrosion and salt spray The detectors electronics must be The sensors must be protected behind sapphire windows The detectors sensitivity response integration time shall be set in either of two by use of a built in switch The S 2406 shall not be for applications with phosphor sodium magnesium hydrogen fires Capability S 2406 is designed to operate with the following listed Pyrotronics Control Panels ZU 35 Module Zone Circuits CZI H2S Style B Class B CZI H4S Style D Class A CZM 4 CZM 1 3 to power requirements a maximum of twelve S 2406 can be connected to a zone due to power requirements a maximum of six S 2406 due to power requirements a maximum of six S 2406 can be connected to a zone can be connected to a zone S 2406 Flame Detector must be installed in accor with N E C 760 and N F P A 72 guidelines Pyrotronics installation and maintenance manual be referenced for detector spacing and sensitivity each particular application The S 2406 is normally wall on an MWV1 swivel bracket at a 45 angle with to the area being monitored Information Voltage A Current on Current Voltage A Information Infrared Detector for S 2406 required Joint Mounting Bracket A A A A sec iA 15 mA Current externally Voltage Current Time Angle sensitivity at temperature and 8Hz switch setting and 2 and 3 W cm2 W cm2 integrating time in seconds switch at setting and 2 and 3 Temperature 13 158 Temperature 40 176 Humidity days year 95 The use of other than Cerberus Pyrotonics detectors and bases with Cerberus Pyrotronics control will be considered a misapplication of Cerberus Pyrotronics equipment and as such all warranties either expressed or implied with regards to loss damage liabilities and or problems Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 9 92