Cerberus Pyrotronics SXL Conventional Zone Fire Alarm Control Panel 7900
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-sxl-conventional-zone-fire-alarm-control-panel-7900-2930547168.pdf |
---|---|
Type | |
Size | 906.97 KB |
Downloads |
Text Preview
SXL Zone Fire Alarm Control Panel AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification Appliance Circuits Multiple Programmable Power Limited 3 Amps Notification and Auxiliary Power 24 and 60 Hour Battery Backup Optional Outputs 4 Open Collector 4 Dry Contact or 8 Dry Contact Relays Subsequent Alarm and Trouble with 24 Hour Reminder Signal Silence Inhibit Sprinkler Supervisory Service Alarm Verification by Zone Alarm Trouble Supervisory and Verification Last Event One Person Test Drill Function Zone Output Bypass Remote Annunciator Option 220 240 VAC 50 Hz Power Supply Option Inherently Power Limited per NEC 760 FM CSFM and NYMEA Approved Listed ULC Listed Cerberus Pyrotronics SXL is another in a family of designed to provide cost effective reliable life equipment to the fire alarm market The micropro based fire alarm control panel is supplied with four zones and is expandable to eight It has features required by today demanding market as field programmability power limited circuits one test feature remote annunciation and sufficient to meet ADA requirements for signaling SXL is designed to meet the varied fire alarm needs small office buildings apartment buildings department hotels strip malls or anywhere a cost efficient purpose fire alarm control panel is required the SXL can be used to supply remote bell for larger systems such as MXL and Features and Features Circuits base SXL has four conventional Style B Class B which are typically compatible with the DI 3 ioniza detector the PE 11 photoelectric detector Cerberus thermal flame and beam detectors and the Series of manual stations Please refer to the detector list in the wiring diagram for specific compat questions combination of 30 compatible smoke detectors can combined on a zone Any number of thermal detectors stations or other compatible direct shorting may be connected to each zone All of these devices can be mixed on the same zone provid the total power requirement of the zone does not 9 mA supervisory current NUMBER system is expanded through the model SZE 4R module which has an additional four initiating in addition to relays and outputs which shall be later system can alternately be expanded through the SZE 8A expander module which has an additional Class A Style D initiating circuits The SZE 8A also the four initiating circuits and the two notification on the main SXL to Style D Class A and Style Z A respectively Appliance Circuits base SXL has two Style Y Class B Notification Circuits each rated at 1.5 Amps The total output of the panel between the two notification and the auxiliary output is limited to 3 Amps The notification circuits are power limited to reduce costs without the addition of any hardware 3 Amps is sufficient to provide power for many requiring appliances designed to ADA specifi Circuits can be programmed for various codes include temporal march time simplified zone code number of rounds They can also be inhibited during and programming functions and Outputs base SXL has form relays for general alarm and rated at 1 Amp 30 VDC The model SZE 4R expander module has an additional four general programmable relays rated at 2 Amps 30 VDC four programmable open collector outputs the model SRC 8 relay module provides eight purpose programmable relays rated at 2 Amps VDC 120 VAC All remote operations in the fire alarm are controlled from the SZE 4R or the SRC 8 both which are installed within the SXL enclosure and Audible Indicators SXL has visible LED annunciation by zone for alarm trouble Additionally there is a system alarm LED and system trouble LED Supervisory zones utilize the zone LED flashing in sync with a system supervisory to indicate an off normal situation with the system alarm trouble and supervisory are also LEDs for AC power bypass and test mode A seven segment display reports a code each system trouble and is also used during testing programming functions Trouble conditions are also by a piezo electric sounder housed inside the annunciation is accomplished with the model or LED 4 eight zone LED annunciators These units alarm supervisory and trouble conditions for 8 A total of two modules can be attached to each The LED 3 comes with a black enclosure the with a white enclosure Power SXL contains a 1 2 Amp auxiliary power circuit which used to drive remote devices The total power of the between the auxiliary output and the two notification is 3 Amps Supply Battery Charger power supply accepts a 120 VAC 60 Hz input or a 220 240 VAC 50 Hz input On loss of AC the system switches to battery operation and such by flashing the AC power LED on the Battery capacities of 24 and 60 hours are avail See accompanying chart for model numbers and Controls SXL display has four switches for acknowledging supervisory and trouble conditions silencing appliance circuits resetting the system and for drill function These switches are also used when the control unit Programmability and Test Functions following functions are field programmable in the These features are generally not programmed in the as received from the factory Field programming is through the display and does not require use of a computer or any proprietary tools Circuits Verification by Zone Zone Bypass Supervisory or Generic Zone when the SXL is to be used to remote notification appliance circuits The default mode is an alarm causing zone Appliance Circuits Simple Zone Coding March Time California Uniform Fire Code Silence Inhibit Timers and Reminders The default mode is a steady signal Outputs Relays Programming to Output Matrix and Password Maintenance tests features include the One Person Test feature Lamp Test and Search and Clear of the alarm trouble supervisory history buffer While in the test mode the is capable of receiving and initiating alarms except those zones under test or bypass Speciifications and Arch and Archiitect Spec fire alarm control panel shall be a Cerberus Pyrotron SXL shall utilize conventional zones shall be micro based and fully field programmable The base shall include four initiating zones relays for general and trouble and two power limited notification capable of a total of 3 Amps of power fire alarm control panel shall be UL ULC listed and the requirements of NFPA 72 for local fire alarm for automatic or manual service and for sprinkler and waterflow service shall meet NFPA 71 requirements for central station when connected to the model 5128 or 5129 digital communicator system shall be expandable via a model SZE 4R module which shall contain an additional four zones four general purpose relays and four purpose open collector outputs fire alarm system shall have the following features alarm and trouble one person test feature out protection 24 or 60 hour battery backup It shall have the following selectable features supervisory alarm verification by zone non latching zones trouble and supervisory history notification appli circuit coding alarm trouble 24 hour reminder and bypass initiating device circuit shall have the capability of mapped to any optional output via the system function Information Information Number Number Assemblies Items Fire Alarm Panel Expander Module A Expander Module Output Relay Module Tie Leased Line Fire Alarm Panel w Front Construction Fire Alarm Panel w Enclosure Fire Alarm Panel VAC 50 Hz Annunciator Black