Cerberus Pyrotronics SZE-4R Zone Output Expander Module 7904
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-sze-4r-zone-output-expander-module-7904-1325780469.pdf |
---|---|
Type | |
Size | 816.14 KB |
Downloads |
Text Preview
SZE 4R Expansion Module for SXL Expansion Module for SXL AND ARCHITECT SPECIFICATT IONS AND ARCHITECT SPECIFICA Expands SXL from 4 to 8 Zones Style B B Zones Selectable as Alarm Supervisory or Generic Input Programmable Output 4 Open Collector Dry Contact Relays 30 Smoke Detectors per Zone Listed ULC Listed CSFM and NYMEA Approved Cerberus Pyrotronics SXL is another in a family of designed to provide cost effective reliable life equipment to the fire alarm market The Model expands the base SXL from 4 to 8 zones the capacity of the system The SZE 4R is UL listed listed and approved by the City of New York and the of California and Features and Features Circuits SZE 4R has four conventional Style B Class B zones are typically compatible with the DI 3 ionization the PE 11 smoke detector Cerberus Pyrotronics flame and beam detectors and the MS Series of stations Please refer to the detector compatibility in the wiring diagram for specific compatibility ques combination of 30 smoke detectors can be combined a zone Any number of thermal detectors manual or other compatible direct shorting devices may connected to each zone All of these initiating devices be mixed on the same zone providing the total power of the zone does not exceed 9 mA supervi current and Outputs base SXL has form relays for general alarm and rated at 1 Amp 30 VDC The model SZE 4R module has an additional four general purpose programmable relays rated at 2 Amps 30 VDC only plus four programmable open collector Programmability and Test Functions following functions are field programmable in the SXL features are generally not programmed in the unit received from the factory Field programming is accom through the display and does not require the use a computer or any proprietary tools Circuit Types Verification by Zone Zone Bypass Supervisory or Generic Zone when the SXL is to be used to remote notification appliance circuits The default mode is an alarm causing zone Appliance Circuit Programming Options Simple Zone Coding March Time California Uniform Fire Code Silence Inhibit Timers and Reminders The default mode is a steady signal Control Options Outputs Relays Programming Options to Output Matrix and Password Maintenance NUMBER test features include the One Person Test feature a Test and Search and Clear of the Alarm trouble and history buffer While in the test mode the is capable or receiving and initiating alarms except those zones under test or bypass Information Information Number SZE 4R Number Expander Module SXL w Outputs Connection Diagram Connection Diagram DEVICE CIRCUIT RATINGS DETECTORS Loop No All field wiring must be in accordance with NFPA 70 Article 760 Make no wiring connections while the System is powered Alarm Relay Contacts are shown de energized and Trouble Relay Contacts are energized Suitable for resistive load only Auxiliary output rated 0.5 amps at 24 VDC filtered Maximum line impedance Combined current output for NAC1 NAC2 and auxiliary outputs is limited to 5 ohms amps Equipment connected to these terminals must be located within the same room Refer to the SXL Operation Installation and Maintenance Manual P N 315 for further details No T Tapping allowed See SXL Operation Installation and Maintenance Manual P N 315 092419 Form C RELAY Form C RELAY RATINGS RATINGS at 30 VDC Resistive Only at 30 VAC Resistive Only COLLECTOR COLLECTOR RATINGS RATINGS max at 26.4 VDC max Connect standby batteries only to terminals B and B The batteries may be in either the bottom of the cabinet or in a UL listed battery enclosure In all cases Cerberus Pyrotronics model number is the compatibility identifier the control panel module s and all compatible initiating devices When using the SLT 1 module not suitable for remote station protected service where separate transmission circuits are required for fire and trouble signals All power limited wiring requires separation from non power limited wiring to the SXL Power Limited Wiring Instructions P N 315 093669 Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 www cerbpyro com in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 3 96