Cerberus Pyrotronics TRI-B6 B6R B6D Intelligent Initiating Interface Modules 6168

File Preview
File Preview
Click below to download for free

Text Preview

TRI B6 Series Initiating Devices Interface Modules AND ARCHITECT SPECIFICATIONS Interface Modules For XL3 Interface Modules For XL3 and IXL Control Panels and IXL Control Panels TRI B6R TRI B6D TRI B6R TRI B6D and Supervises Normally Open Fire Detection Normally Closed Contacts Security Detection SPDT Relay Model TRI B6R Input Model TRI B6D Microcomputer Chip Technology Technology Supports Comprehensive System Interface Communication Supervision Wire Operation Model FPI 32 Programs and Verifies Address and Tests Device Functionality Address Programming is Easier and Dependable ULC Listed CSFM City of Chicago NYMEA and FM Approved Pyrotronics TRI B6 Series Intelligent interface are designed to provide the means of interfacing shorting devices to the MXL system ALD loop the IXL system ICon loop circuit or to the XL3 INX loop circuit Pyrotronics TRI B6 Series Intelligent interface provide the market most advanced method of programming and supervision combined with control panel communication Each TRI B6 interface module incorporates a microcomputer The TRI B6 Series microcomputer chip technology its sophisticated bi directional communication capa with the control panel achieve the state of an Device TRI B6 Series intelligent interface modules are avail in three models The TRI B6 and TRI B6R are to monitor a normally open or closed dry con The interface module reports the contact status to control panel The TRI B6 model can only monitor and the status of the contact while the TRI B6R incorpo an addressable Form C relay The TRI B6R relay contact device input are controlled at the same For the XL3 and MXL system the relay and input can be controlled as a separate function while for IXL they are controlled as a related function The relay typically used where control or shunting of external is required TRI B6D is a dual input module and is designed to and monitor two sets of dry contacts This module requires two address settings The TRI is ideal for monitoring a waterflow switch and its valve tamper switch TRI B6D Series devices can also be used to monitor status of normally closed security switches device microcomputer chip has the capacity of in memory identification information as well as operating status information In addition the Series interface modules using their microcomputer can communicate in either of two protocols XL3 or for the MXL and IXL ICon Pyrotronics innovative technology allows all TRI Series intelligent interface modules to be programmed using the SensorLINK model FPI 32 Programmer Tester FPI 32 Programmer Tester is a compact portable NUMBER driven accessory that makes programming and an interface device faster easier and more depend than previous methods The FPI 32 eliminates the for mechanical addressing mechanisms such as jumpers DIP switches or rotary dials because FPI 32 electronically sets the TRI B6 interface into the interface microcomputer chip non memory Vibration corrosion and other conditions deteriorate mechanical addressing mechanisms are longer a cause for concern TRI B6 Series is fitted with screw terminals for connec to an addressable circuit TRI B6 Series is fully compatible on the same MXL or circuit with all intelligent IL and ID 60 Series detectors Series addressable manual stations or any other intelligent modules such as the CZM or ICP TRI 60 Series is fully compatible on the IXL ICon with all intelligent IL and ID 60 detectors and MSI stations Pyrotronics FPI 32 Programmer Tester The programmer shall be menu driven Once the address is entered the programmer shall set and the address The programming accessory shall also capable of testing the interface functionality The interface module address shall be set by means only No mechanical means such as pins DIP switches or rotary dials shall be TRI B6 Series shall be compatible on the same XL3 or circuit with other Cerberus Pyrotronics intelligent IL ID 60 Series detectors TRI Series addressable MSI Series addressable manual stations or any Cerberus Pyrotronics XL MXL addressable intelligent The TRI B6 Series shall be compatible on the IXL ICon circuit as other intelligent IL and ID 60 detectors MSI Series manual stations and TRI interfaces Information Information Input Input w Relay Input Wt oz oz oz TRI B6 Series intelligent interface modules are UL operating conditions for all TRI B6 Series are 32oF oC to 120oF 49oC with a relative of not greater than 93 non condensating and Architect Specifications and Architect Specifications addressable interface module shall incorporate a microprocessor based integrated circuit that shall communication with its compatible control panel addressable interface module shall be a Cerberus TRI B6 Series that shall be compatible with a Pyrotronics IXL MXL or XL3 control panel Pyrotronics TRI B6 Series intelligent interface shall provide the means of interfacing direct devices to the control panel addressable The intelligent interface modules shall be avail in three models The TRI B6 and TRI B6R shall be to monitor a single normally open or normally dry contact The interface module shall report the status to the control panel The TRI B6 model only monitor and report the status of the contact the TRI B6R shall incorporate an addressable Form relay The TRI B6R relay and contact device input shall controlled as a separate function at the same address the XL3 or MXL control panel The TRI B6D shall be a input module designed to supervise and monitor two of dry contacts This interface module shall require address settings TRI Series devices shall be capable of and listed for normally closed security switches to the MXL or per UL 1076 addressable interface module shall be UL listed addressable interface module shall be dynamically and uniquely identifiable by the control panel addressable interface module address shall be with the use of a portable programming The programming accessory shall be a inches Do not use conduit entry INCH DEEP GANG SUPPLIED GANG BLANK SUPPLIED Rear conduit entry not recommended only clearance Data Data Interface Model TRI B6 TRI B6D TRI B6R directly into a 3 and 1 2 inches deep double gang user supplied only Each module is secured to switchbox with a standard blank double gang switch also user supplied Refer to Figure 1 for details Wiring Wiring to Figures 2 3 4 5 6 or 7 Refer to the appropriate diagram below and wire the addressable interface accordingly wire size AWG minimum AWG maximum larger that 14 AWG can damage the screw terminals There can be any number of normally open switches The end of line resistor must be located at the last switch Do Not wire a normally closed switch across the end of In security applications an open or short causes a resistor alarm Alarm Trouble Use Open Open Open 2 Supervisory Open Normally Open Switches Use Closed There can be any number of normally open switches The end of line resistor must be located at the TRI An open causes a security alarm 3 Normally Closed Switches Only 4 Power Limited Wiring XL3 All supervised switches must be held closed for at least 15 seconds to guarantee MXL All supervised switches must be held closed and or open for at least a quarter of a to guarantee detection of line device 3.6K ohms resistor P N 140 820185 supervised switches have the following ratings maximum ma

Related Files