Cerberus Pyrotronics TSP-40 Thermal Strip Printer 5007
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-tsp-40-thermal-strip-printer-5007-2193068457.pdf |
---|---|
Type | |
Size | 1.03 MB |
Downloads |
Text Preview
TSP 40 Thermal Strip Printer AND ARCHITECT SPECIFICATIONS Event Logging 40 80 Character Line Modes System Reports Battery Backup Paper Take Up Reel Out of Paper Indication Event Buffer Full Message When of Paper RS 232C Communication Listed CSFM FM and City of Approved TSP 40 is a thermal strip printer designed for use with Cerberus Pyrotronics MXL system It mounts in the enclosure and its printout is visible through a window the locked enclosure door Printouts are automatically on a take up reel for easy record storage TSP 40 acts as an event logging device providing a history report of all MXL system activity It can be used to provide system status reports including a of all smoke detector sensitivities and thresholds It also supply a listing of device analog voltages device and custom messages TSP 40 operates from the MXL main power and will to function if the MXL transfers to standby This battery backed up operation assures event during an AC power loss without the need for a TSP 40 uses thermal printer paper and can operate in normal and compressed character modes System such as Alarm and Troubles are indented and in caps for easy identification System reports are in compressed 80 character mode All events and are printed with the time and date The MMB also a printer test at midnight each day and Architect Specifications history logging of all system events shall be by the TSP 40 thermal strip printer The printer be mounted in a locked enclosure and printout shall visible through an opening in the enclosure door All shall be automatically spooled onto a take up printer shall operate from a 24 VDC supply and shall to operate from the system standby batteries in event of main power loss No UPS system shall be for backup power TSP 40 shall record all system events including commands and shall be capable of providing a list of system condition such as detector sensitivi thresholds analog voltages device type and custom A trouble condition shall be generated when paper has run out An internal buffer shall continue store events when paper is out NUMBER Data Wiring Installation TSP 40 comes with two attached cables a two conduc power cable and six conductor data cable To complete electrical installation Connect the six conductor data cable to P4 on the If no MOM 4 is installed connect the two conductor cable to P3 on the MMB 1 If a MOM 4 is installed connect the two conductor cable to P8 on the MOM 4 The use of other than Cerberus Pyrotonics detectors and bases Cerberus Pyrotronics control equipment will be considered a of Cerberus Pyrotronics equipment and as such void all either expressed or implied with regards to loss damage and or service problems Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1996 sheet dated 9 95