Cerberus Pyrotronics VSM-1 VLM-1 Operator Switch Module LED Annunciator Module 5023

File Preview
File Preview
Click below to download for free

Text Preview

VSM 1 VLM 1 VFM 1 Operator Switch Module MXLV Annunciator Module MXLV Fan Control Module AND ARCHITECT SPECIFICATIONS Eight Programmable Protected Space for Labeling Discreet Switches Multi Color LED For Indication Of Status Modular Programmable LED Listed ULC Listed CSFM FM City Chicago Approved 4 Programmable Fan Switches Rotary H O A Manual On Off Positions Positive Feedback LED Indication of Fan On Off and Protected Label Modular Activation Stagger Timer Listed ULC Listed and CSFM VSM 1 is an MXLV Command Console option module provides manual control of the Emergency Voice System Each VSM 1 module provides eight push button switches and 16 LED to their status Each switch is assigned two LED a label to indicate the switch programmed usage label slides behind a clear protective membrane of the LED assigned to each switch is a dual color used to indicate what type of signal is active This may also be lighted steady or flashing to further system status For example zones active to the audio channel will have the LED lighted RED steady zones active to the Alert audio channel will the LED lighted RED and flashing zones selected paging will have the LED lighted GREEN and flashing the microphone key is pressed when the zone confirmation message is received by the MXLV Console the LED will change to steady indicating that it is clear to page telephone with a call in in progress will have their LED RED until selected at the Command Console at time the LED will convert to steady RED etc This NUMBER the operator easy clear access to the overall condition at all times The second LED is amber is used to indicate a fault condition VSM 1 and each switch is fully programmable and be used to control speaker circuits and a wide of general system functions such as All Call All Warden Page Local Speaker Select etc Any of circuits may be grouped and controlled by a switch Switch usage and zone groupings are using AccuLINK system programming soft VSM 1s are mounted on a hinged panel as a part of MXLV Command Console enclosure A four conduc cable is supplied for interconnection of the modules 12 cable Model MRRC 1 is available for connection rows VSM 1 connects to the TBM 1 module mounted in enclosure equipment is approved for operation over the range of 0 to 49 VLM 1 is an MXLV option module which provides annunciation of system activity Each VLM 1 module eight groups of 2 LED each of which can be to desired outputs using the AccuLINK pro software Eight LED are dual color capable being lighted either RED or GREEN flashing or steady remaining LED are AMBER flashing or steady space is provided for labeling of LED functions The slides behind a clear protective membrane VLM 1 dimensions are identical to the VSM 1 and is on the same hinged panel as a part of the MXLV Console enclosure A four conductor cable is for interconnection of the modules A 12 cable MRRC 1 is available for connection between combination of VSM and VLM modules may be used equipment is approved for operation over the range of 0 to 49 VFM 1 is an MXLV command console option module provides manual control of building HVAC system motors and dampers Each VFM 1 module provides rotary 3 position switches for manual system control H O A Hand Off Auto switches provide a visual of the switch state Off On or Automatic and its associated control outputs by both switch position indication and LED status indica Each switch has 3 associated LEDs to indicate Fan status OFF Red LED ON Green LED Yellow LED in the automatic position the red and green LEDs fan status On or Off based on the system logic can be programmed to automatically control the fan When manually switched to the Off position the LED will flash indicating that the output circuit used turn off the Fan Damper Motor has activated The red will light solid red to indicate positive feedback of Fan Damper Motor actually turning off via a moni input When manually switched to the On position green LED will flash indicating that the output circuit to turn on the Fan Damper Motor has activated green LED will light solid green to indicate positive of the Fan Damper Motor actually turning on a monitored input See chart below system reset when switches are turned manually the or the position their associated do not change state They stay either On or Off on the switch position Outputs will only change when manually controlled via the On Off switch or on system logic when switch is in the Auto posi Indications Red Solid Green Solid Flashing Solid Flashing Solid on System Logic Driving Fans Sent Out to Turn On Fans On Positive Feedback Received Fan is On Sent Out to Turn Off Fans Off Positive Feedback Received Fan is Off VFM 1s are mounted on a hinged panel as a part of MXLV command console enclosure A four conductor is supplied for interconnection of the modules A cable MRRC 1 is available for connection between VFM 1 switch is fully programmable Many outputs or relays may be grouped and controlled by a switch When more than one fan is controlled by a VFM 1 switch an optional programmable stagger can be set to prevent all fans from turning on 0 255 seconds Switch programming zone usage groupings are assigned using AccuLINK programming software combination of the VSM VLM or VFM modules may used up to 31 modules per ACM 1 equipment is approved for operation over the range of 0 to 49 and Architect Specifica control and annunciation of system status shall provided by a set of modular switch units model Each module shall include eight discreet push button switches Units using mem type switches for this purpose will not be accept switch shall include space for labeling switch The label shall slide behind a clear protective addition each switch shall have two LED associated it One of the LED shall be dual color and capable clearly indicating zone status including which audio is active Systems which indicate only zone without indicating the type of signal which is i e Evacuation Alert Page etc will not be to the position or based on system logic Green flashing shall indicate that a manual has been sent out to turn on a fan Green solid indicate that positive feedback has been received the fan is On shall be easily configured using AccuLINK programming software Many fans can be to a single switch When more than one fan is by a single switch an optional stagger time be programmable to prevent all fans from turning simultaneously control modules shall mount in a hinged panel to easy access to the rear of the module The address shall be set using a dip switch on the of the unit Modules shall be interconnected using a four conductor cable supplied with the unit Information Module 8 Switches Annunciator Module 8 LED Sets Control Module 4 3 Position On Off Auto Cable 4 Conductor Frame 14 Module Openings Frame Openings for 8 and TSP 40 Strip Printer Frame for MSE 2 5 Module Blank w Overlay Instructions VSM VLM VFM 315 092064 No switch shall also include an amber LED to indicate fault condition on a zone or zones associated with that and LED shall be easily configured using system programming software Any number of strobe or telephone zones may be mapped to a switch modules shall be mounted in a hinged panel to easy access to the rear of the module Module shall be set using a DIP switch on the rear of the Modules shall be interconnected using a polarized conductor cable supplied with the unit A 12 cable MRRC 1 shall be available for connection

Related Files