Cerberus Pyrotronics ZCT-8B Plug-in Fire Fighter Telephone Zone Card 5031
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-zct-8b-plug-in-fire-fighter-telephone-zone-card-5031-6523794108.pdf |
---|---|
Type | |
Size | 1.17 MB |
Downloads |
Text Preview
ZCT 8B Firefighter Telephone Zone Card AND ARCHITECT SPECIFICATIONS Firefighter Telephone Circuits Plugs Into OMM 1 and OMM 2 Call in Acknowledge Tone Command Console Tone Separate Call in And Circuit Shorted Power Limited Circuits Warden Page Option Manual or Fully Programmable ULC Listed FM CSFM and City of Chicago ZCT 8B is an MXLV option module which plugs into a on the OMM 1 or OMM 2 cardcage providing 8 telephone zones The zones can be configured have an off hook acknowledge tone as well as a Com Console busy tone zone is activated when a firefighters telephone FT 301 302 series connected to that zone is taken or a portable handset PT 303 304 series is into a jack FJ 303 series When the zone active the remote telephone station will receive off hook acknowledge tone and the programmed zone will begin flashing at the Command Console Once by the operator the zone will be connected to the riser in a party line mode If the signal has been enabled the active remote telephone will receive a busy tone when the Command is presently connected to another telephone telephone zone uses a single pair of wires shielded is individually supervised in a Class B type mode are also individually power limited per NEC 760 zone also contains transient protection Up to 6 stations may be off hook simultaneously with no of audio quality ZCT 8B is supplied with a KEY which when inserted the slot on the OMM 1 or OMM 2 will prevent any type of module from being inadvertently placed in location edge connectors on the ZCT 8B are gold plated for reliability and Architect Specifications Telephone circuits shall be provided by a plug type module which supplies eight individually super and power limited circuits Each circuit shall use a pair of shielded wires min 18 AWG and shall be of providing both an off hook acknowledge and a Console busy signal telephone zone module shall plug into an OMM 1 or cardcage as a part of the Cerberus Pyrotronics Emergency Voice Evacuation system Edge connec shall be gold plated for maximum dependability to 6 firefighters telephones either stations or portable may be active simultaneously with no noticeable of audio quality warden station on a telephone zone shall be capable acting as a wardens page microphone in either a console controlled mode or automatic mode NUMBER Ratings Electrical Characteristics Maximum wire size Minimum wire size Maximum loop Outputs End of line resistor AWG twisted pair shielded AWG twisted pair shielded ohms for both wires 9 VDC 9mA max 12.5 VDC 300mA 1 4W 1 140 383467 Diagram Information No firefighter s telephone zone No Instructions telephone equipment telephone station telephone station with cable telephone station with switch telephone station with switch and armored portable handset jack handset back box back box w key lock glass for FC 300S The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics equipment will be considered a misapplication of Cerberus Pyrotron equipment and as such void all warranties either expressed or implied with regards to loss damage liabilities and or service problems Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1996 sheet dated 8 94