Siemens AA-30U AE-30U System 3 Audible Alarm Extender Modules, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data 3TM Alarm Extender Modules AA 30U AE 30U Y or Z circuit operation AND ENGINEER SPECIFICATIONS Light emitting diode LED Trouble indicator Placement supervised AC or DC audibles UL 864 9th Edition Listed ULC Listed CSFM and New York City Fire Department Approved Overviews AA 30U Alarm Extender Module Model AA 30U from Fire Safety is designed for use with the 3 fire alarm control panel FACP and meets requirements of NFPA 72 A Z AA 30U provides a 4 four wire circuit for polarized parallel connected 24 VDC notification appliance circuits NACs The capacity is typically 20 vibrating DC bells 10 horns or strobes Additional bells horns or can be added depending on the current of the connected devices based upon condition that the total circuit load does not 1.5 Amps of the module is caused by a high pitch signal from a system control module Dual activation terminals are provided for or sequencing its operation AA 30U contains a yellow Trouble LED on the face of the module indicating an or shorted loop condition The Trouble LED is operative at all times except when the is in Alarm mode AA 30U is placement supervised providing a Trouble signal upon removal from the system power for the Alarm circuit is fused within module The fused circuit requires an end of line resistor rated 5.6 Ohms 0.5 Watts Industry Inc Technologies Division AE 30 Alarm Extender Module Model AE 30U from Fire Safety is designed for use with the 3 FACP and meets the requirements of 72 A Z AA 30U provides a 4 four wire circuit for polarized parallel connected 24 VDC or 120 VAC NACs The circuit capacity depending on the device type and rating total circuit load must not exceed 1.5 Amps of the module is caused by a high pitch signal from a system control module Dual activation terminals are provided for or sequencing its operation AE 30U contains a yellow Trouble LED on the face of the module indicating an or shorted loop condition The Trouble LED is operative at all times except when the is in Alarm mode AA 30U is placement supervised providing system Trouble signal upon removal from the The 2 two wire circuit on which Model is fused requires an EOL resistor rated at Watts for DC devices and 5.0 Watts for AC 3TM Audible Alarm Extender Modules 3129 Diagrams AA 30U AE 30U Ratings Input Power and Humidity Range AA 30U AE 30U are UL 864 9th Edition for indoor dry locations within a temperature of 120 3 49 2 to 32 3 0 2 at a relative humidity of 93 2 a temperature 90 3 32 2 for Ordering 500 884310 500 884320 A Alarm Module space Module space 0.45 Kg 0.45 Kg This marketing data sheet is not intended to be for system design or installation purposes the most up to date information refer to product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2011 sheet dated 8 05

Related Files