Siemens ASD Filter box FDAZ292 Mounting Maintenance

File Preview
File Preview
Click below to download for free

File Data

Name siemens-asd-filter-box-fdaz292-mounting-maintenance-4726310958.pdf
Type PDF
Size 1.24 MB
Downloads

Text Preview

FDAZ292 filter box Infrastructure specifications and availability subject to change without notice reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages rights created by patent grant or registration of a utility model or design patent reserved by Switzerland Ltd Infrastructure Headquarters 1a Zug 41 58 724 2424 2020 04 07 ID A6V10877841 en b Siemens Switzerland Ltd 2016 18 of contents this document documents history for ordering site filter box data pattern compatibility and disposal 18 18 this document About this document and purpose document contains all information about the ASD filter box FDAZ292 the instructions consistently will ensure that the product can be used and without any problems ASD filter box is used in environments with a high dust It is installed in the pipe system upstream of the aspirating smoke FDA to provide protection against contamination The ASD filter box dust and dirt particles out of the pipe system before they can get to the smoke detectors This increases the service life of the aspirating smoke ASD filter box comprises a plastic housing ABS and an ASD filter set with separate filters with pores of different sizes coarse medium fine use ASD filter box is only permitted for use to filter dust and dirt particles of the pipe system for the aspirating smoke detectors FDA groups information in this document is intended for the following target groups Is responsible for information Has obtained suitable specialist between the manufacturer regional company for the function and for the Coordinates the flow of information Has attended the training courses the individual groups of involved in a project Product Managers at the place of Carries out a function check installation Carries out all maintenance work Checks that the products are in working order Searches for and corrects Has received specialist training in area of building installation or electrical installations Has obtained suitable specialist for the function and for the language and reference document The source original language of this document is German de The reference version of this document is the international version in English international version is not localized identification document ID is structured as follows group Manager personnel personnel Assembles and installs the product 18 this document code 1 generated by the STEP system abbreviation in accordance with ISO abbreviation in accordance with ISO 3166 1 or international version single or double digit a b aa ab bb Some documents have different ID codes that are generated by an earlier There are also documents with up to date ID codes along with features in the designation code multilingual or international format date format in the document corresponds to the recommendation of standard ISO format YYYY MM DD for text marking markups are shown in this document as follows for a behavior instruction instruction with at least two operation sequences option or detailed information for a behavior instruction result of a behavior instruction result of a behavior instruction lists and behavior instructions with an operation to a page number reproduced identically of keys sign and for identification between steps in a sequence Menu bar Help Help topics of a glossary entry X information and tips i symbol identifies supplementary information and tips for an easier way of 18 this document documents Applicable documents ID Mounting Aspirating smoke detector FDA241 FDA221 manual Aspirating smoke detector FDA241 FDA221 Installation ASD Pipe system Revision history reference document s version applies to all languages into which the reference is translated first edition of a language version or a country variant may for example be d instead of a if the reference document is already this version date table below shows this document s revision history description Installation site Installation dimensions changed edition 18 for ordering Details for ordering number filter box filter set of delivery filter box incl ASD filter set with three filters with pores of different sizes medium fine ASD filter set is available to order as a spare part 18 site Mounting Installation site 1 Installation site 18 filter box ASD filter box 18 max 4360 Maintenance intervals for replacing the ASD filter set are determined by the dust in the ambient air intervals If the air is heavily contaminated as is the case in cement works or recycling for example every two to three months In the case of average air contamination as is the case in a production facility a lift shaft for example every six months In air that is only slightly or occasionally contaminated every twelve months the ASD filter set with all three foams To optimize transport time the two with coarse and medium sized pores are sufficient also Details for ordering 18 18

Related Files