Siemens CDC-4 (for FireFinder) Conventional Detector Card, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-cdc-4-for-firefinder-conventional-detector-card-data-sheet-8367109452.pdf |
---|---|
Type | |
Size | 886.71 KB |
Downloads |
Text Preview
Catalog XLS Detector Card CDC 4 Supports up to 30 Siemens conventional smoke detectors per zone Four 4 A or B zones Supports various detectors manufactured by others Supports unlimited shorting devices per zone Supports one 1 beam detector per zone Mounts in single slot of card cage Optional alarm verification by circuit Ground fault detection Plain decimal address setting Custom message by zone available Built in diagnostic light emitting diodes LEDs UL 864 9th Edition Listed ULC listed CSFM and NYMEA Approved Overview Conventional Detector Card Model CDC 4 is to monitor Siemens Fire Safety conventional on the FireFinder XLS system Model can be used in applications where detectors are more suited than detectors such as hallways or large rooms CDC 4 can also be used to upgrade Siemens fire alarm panels to the FireFinder system without requiring detector replacement of the four 4 conventional zones can be wired A Style D or Class B Style B Up to 30 photo photo thermal or ion can be wired to a single zone A zone optionally support a single beam detector zone can also have an unlimited number of open contact devices such as manual stations and thermal detectors detectors can use an audible base a relay or a remote LED The appliance will activate that detector goes into Alarm mode View View zone can operate the appliances associated with the smoke detector in Alarm mode Each zone can also be to operate with the Alarm Verification feature This helps reduce nuisance alarms by automatically an Alarm event received on the zone caused by detectors The zones can also each be configured for operation allowing partial system functions the system loses communication with the main control unit operational characteristics and the custom message each zone are programmed using the ZEUS programming and is stored within the system Addressing Model is performed using the integral 3 three position address switches located on the front of the card LEDs on Model CDC 4 give indication of communication ground fault by card alarm by and trouble by circuit These LEDs aid in problems found on a system A local reset for Model CDC 4 card is also provided CDC 4 mounts in a single slot of a Model CC 5 or Model cardcage Field wiring for Model CDC 4 is connected the upper terminals on the cardcage while 24VDC is to the lower terminals for powering the zones Conventional Detector Card 6328 Industry Inc Technologies Division Ratings s Fire Safety 30 per zone unless indicated 4 per zone DF 1192 DI 3 3H DI A3 A3H DI B3 B3H DT 11 DT 135R 135F DT 135CL 135CS 135WP unlimited DT 200R 200F DT 200CL 200CS 200WP unlimited DT 3P 135 DT 140EP 160EP 190EP 225EP 275EP 365EP 450EP PBA 1191 PE 3 3T PE 11 11T S 121 122 1 per zone per zone per zone non s Fire Safety supports the following non Siemens detector Air Products and Controls Apollo Signal Hochiki to installation sheet or technical website for models and supported Contact manufacturer for listing information on models and Humidity Range are UL 864 9th Edition Listed for indoor dry within a temperature range of 120 3 to 32 3 0 2 and a relative of 93 2 at a temperature of 90 3 for Ordering Conventional Detector Card This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2011 sheet dated 5 10 3