Siemens Cerberus DMS Specification Texts V4 2

File Preview
File Preview
Click below to download for free

File Data

Name siemens-cerberus-dms-specification-texts-v4-2-1783506492.pdf
Type PDF
Size 821.55 KB
Downloads

Text Preview

DMS Version 4.2 Texts Infrastructure of Contents Notice 3 to the Danger Management System 4 4 requirements expected 5 disclaimer 7 Unrestricted Infrastructure Copyright Notice information is subject to change without notice by Siemens Switzerland Ltd Companies and various data used in examples are fictious unless otherwise noted No part of this may be reproduced or transmitted in any form or by any means electronic or mechanical any purpose without the express written permission of Siemens Switzerland Ltd software described in this document is furnished under a license agreement and may be used or only in accordance with license terms further information contact your nearest Siemens Switzerland Ltd Representatives Siemens Switzerland Ltd 2018 and Cerberus DMS are registered trademarks of Siemens Switzerland Ltd products or company names mentioned herein may be the trademarks of their respective 2020 04 14 ID A6V12013743 Unrestricted Infrastructure to the Danger Management System Danger Management System hereafter called DMS shall be a professional management system the full breadth of application support for ensuring life safety property safety and keeping protected shall allow for central monitoring and control of all the fire safety video surveillance access control intrusions installations configured in our premises of this document is to identify the key requirements to be supported by a DMS Unrestricted Infrastructure Key requirements expected system shall be based on an open management platform with a flexible full client server allowing scalability from small and medium systems to large and complex systems system must be certified to run on both physical and virtual environments Compatibility with Vsphere Stratus and Hyper V Virtualization supporting High Availability configurations DMS user interface shall present well arranged relevant information to the user It shall be ready interaction without any overlapping windows and shall be coupled with event oriented workflows communication and approved fire norm conformance system shall be designed for use with fire safety and security systems and enable users to Visualize and handle events for example acknowledge silence and reset Graphically monitor and control life safety and security systems Know where to start as the highest priority events are highlighted Maintain continuous situational awareness of all fire and security panels with the graphical Map dashboard Directly navigate with just one click to the triggering element of an event Quickly navigate to custom operator instructions and graphical display of event locations Store and retrieve fire alarm system activity data Distribute fire access video and intrusion monitoring and control capabilities across a of DMS management clients Provide Operating Procedure checklists to guide the operator under stressful conditions in significant events Display multiple video streams Automatically or manually via graphical easy buttons send out remote notifications via SMS and pagers with multi level escalation and exclude isolate de isolate system devices View and schedule automatic history reports View and schedule automatic operator tasks with revert action Provide To Arm check for Intrusion Monitor and operate video surveillance systems Typical video surveillance workflows shall supported including display of live video streams PTZ and preset operations recording and recording bookmarks search and replay and multi camera operations for procedures camera groups and camera sequences Manage monitor walls and share video information and operations across the system View and handle the alarms and objects of the DMS from iOS and Android mobile phones tablets Mobile App Print out an ongoing record of the system operation Journaling the system shall a web based user interface that offers the same functionality as those on other including operation and configuration Web Client an online engineering concept that speeds up project commissioning time and system downtime Unrestricted Infrastructure Support a powerful and flexible library concept that allows on the one hand of system operation and on the other a further drastic reduction of time Provide means for storing and archiving data for a period of more than 10 years allowing as option segregation of stored data in different groups Support multiple languages in the same project configuration Project data as well as user texts shall be displayed in the language of the user who is logging on the system Support a wide range of product families from Fire Safety and Security systems Support open standard protocols including BACnet OPC DA Modbus TCP ONVIF SNMP communicate with 3rd party devices Communication options shall include local and connections Allow for custom extensions by means of a software development kit SDK to develop drivers not supported by the system natively for communication with 3rd party and devices or exchange of data with external applications by using the REST Representational State Transfer web service interfaces The system must provide possibilities to extend the functionality by adding new libraries containing graphic symbols graphic templates or object models to support subsystem or optimize automated tasks Allows Enterprise Applications or other Management Systems to access real time values integrated subsystems via OPC Server supporting the OPC DA Data Access Assure software robustness to cyber attacks and compliance with the computer security the organization ISA 99 IEC 62443 Support the migration from MM8000 management stations Support an efficient engineering of floor plans based on the import of CAD files and an placement of detectors Provide an easy generation of the floor plan graphics with access evacuation route Unrestricted Infrastructure Cybersecurity disclaimer provides a portfolio of products solutions systems and services that includes security that support the secure operation of plants systems machines and networks In the field of Technologies this includes building automation and control fire safety security as well as physical security systems order to protect plants systems machines and networks against cyber threats it is necessary to and continuously maintain a holistic state of the art security concept Siemens only forms one element of such a concept are responsible for preventing unauthorized access to your plants systems machines and which should only be connected to an enterprise network or the internet if and to the such a connection is necessary and only when appropriate security measures e g firewalls network segmentation are in place Additionally Siemens guidance on appropriate security should be considered For additional information please contact your Siemens sales or visit https www siemens com global en home company topic areas future of portfolio undergoes continuous development to make it more secure Siemens strongl

Related Files