Siemens Cerberus PRO Fire Safety Fire-Alarm Enclosures and Equipment, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-cerberus-pro-fire-safety-fire-alarm-enclosures-and-equipment-data-sheet-6075942138.pdf |
---|---|
Type | |
Size | 1.53 MB |
Downloads |
Text Preview
Cerberus PRO Enclosures and Equipment FHB2001 U1 R1 FHB2002 U1 R1 FHB2005 U1 R1 FHD2001 U3 R3 FHD2002 U3 R3 FHD2003 U3 R3 FHD2004 U1 FHD2005 U1 FHD2006 U1 FHD2007 U3 R3 FHD2012 U1 FCM2022 U3 FCM2023 U3 VTO2001 U3 VTO2004 U3 AND ENGINEER SPECIFICATIONS Sheet Used with various Siemens fire control panels FACPs One height unit 1HU two height unit three height unit 3HU enclosures Three height unit enclosures 3HU used only on Cerberus Intelligent Voice Communications IVC panels Inner outer doors Blank plates for inner and outer doors Lens plate for outer door Hinged locking door provides easy to panel components Back boxes Available in either black or red Model FHB2005 U1 is used only on IVC panels Knockouts for field wiring Overview Cerberus PRO fire alarm enclosures and their provide a complete set of hardware for all Cerberus PRO main system and remote cards and modules offering easy capability for a variety of Cerberus PRO system applications the by design allows for future system Included in the enclosure series are back and door sets removable mounting plates and lenses and blank plates for use with the doors enclosures which are FM 3010 FDNY 6104 CSFM 7165 0067 0259 Approved come with straps for the inner and outer doors shield and tie wrap for securing wire grounding PRO one height unit 1HU and two 2HU enclosures can also mount system batteries up to 33AH in capacity and three 3HU enclosures can hold back up up to 55AH PRO Safety Products for infrastructure Ground straps for the inner and doors shield termination lugs lugs and tie wrap lances included UL 864 9th Edition Listed ULC Listed CSFM and NYC Fire Dept Approved 1HU enclosure each Cerberus PRO FACP one 1 red or black box supports one 1 red or black outer door The black inner door specifically stores system operating unit Model FCM2018 U3 or FCM2019 U3 back box supports the fire terminal board Model and optionally supports the Digital Communication Transmitter DACT Model 1HU enclosure is the smallest housing for the PRO systems The following components a complete 1HU enclosure One 1 back box One 1 inner door One 1 outer door Model FHD2001 U3 R3 One 1 clear lens FHB2001 U1 R1 FHD2004 U1 FHD2006 U1 size 15 38.1 cm H 50.8 cm W 11 cm D and equipment Overview continued FHB2001 U1 for One Height Unit Enclosures 2HU enclosure two height unit enclosure is another available for the Cerberus PRO Fire Safety System The components comprise a complete 2HU One 1 back box Model FHB2002 U1 R1 One 1 or two 2 inner doors FHD2004 U1 or FHD2005 U1 One 1 outer door FHD2002 U3 R3 or FHD2003 U3 R3 One 1 or two 2 clear windows FHD2006 U1 One 1 window is installed for Model FHD2002 U3 R3 door and two 2 windows are required for FHD2003 U3 R3 size 28.5 72.4 cm H 50.8 cm W 15.2 cm D FHB2005 U1 for Three Height Unit Enclosures doors 2 types of inner doors are generally used with PRO panel enclosures Model FHD2004 U1 one 1 operating unit Model FCM2018 U3 or LED Model FCM2019 U3 one 1 Microphone VTO2004 U3 one Switch Module or 1 one 4 LED option modules Model FCM2023 U3 less than four 4 LED option modules are used blank option module Model FCM2022 U3 covers module spaces in the inner door Model Model Switch Model VTO2004 U3 FHD2004 U1 Module FCM2023 U3 Model FHD2005 U1 is a solid blank plate to provide dead front protection Inner Door Used with Remote Display Terminals there is an optional inner door that can used on Cerberus PRO 252 504 point addressable panels Model FHD2012 U1 can optionally with Model FT201x series Remote Display RDTs a Model FHD2012 U1 inner door can help preventing unauthorized access to the RDT In compliance of ULC Canadian fire code the FHD2012 U1 Inner Door must be ordered used in RDT installations Customers in Canada see datasheet 9807C for more information rail kit optional DIN Rail Kit Model FHA2031 U1 mounts the back box of a one or two height unit enclosure provides connection between internal system and field wiring PRO FHB2002 U1 for Two Height Unit Enclosures 3HU enclosure three height unit enclosure is the largest housing for Cerberus PRO panels and is used in IVC installations The following comprise a complete 3HU One 1 3HU back box Model FHB2005 U1 R1 Two 2 inner doors Model FHD2004 U1 Two 2 clear lenses Model FHD2006 U1 One 1 outer door Model FHD2007 U3 R3 One 1 blank plate Model FHD2009 U1 R1 An enclosure cover Model FHA2041 R1 is used to the ventilation holes found at the top of 3HU backboxes Model FHB2005 R1 FHA2041 R1 prevents condensation from entering FACP Its design and purpose meets New York City Dept code for protecting uncovered ventilation on fire system enclosures size 42 106.7 cm H 53.3 cm W 19.7 cm D Industry Inc Technologies Division 2 Overview continued clear window window Model FHD2006 U1 comprised of rugged lens is mounted to the opening of the outer door size 10.25 26.04 cm H 43.2 cm W trim kits size enclosure has a trim kit available in black red The trim kit is used for flush mounting a PRO system enclosure Model FHA2035 R1 is used for the one height unit enclosure FHA2036 U1 R1 is used for the 2HU enclosure IVC installations an optional 3HU trim kit can be to provide an aesthetically pleasing appearance an IVC enclosure when used in flush mount Each of these trim kits available in either Model FHA2043 U1 or red Model FHA2043 comes unassembled in four 4 detachable slats easy shipping brackets Cerberus PRO fire only systems a Model FHA2032 battery bracket can be mounted optionally into a backbox in order to secure batteries up to For Cerberus PRO IVC panels a Model battery bracket can be mounted into a system backbox in order to hold up to 33AH and Humidity Range are UL 864 9th Edition Listed for indoor locations within a temperature range of 120 3 49 2 to 32 3 0 2 and a humidity of 93 2 at a temperature of 3 32 2 Industry Inc Technologies Division 3 Technical Data Material Door Colors Box metal 0.062 or black metal 0.062 annealed Material Surface Doors I Material clear Lexan Door Back Box W x H x D Door W x H x D 21.5 1.0 cm x 9.8 cm x 4.5 cm