Siemens CH Notification Appliances Chimes and Chime Strobes, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-ch-notification-appliances-chimes-and-chime-strobes-data-sheet-2479603185.pdf |
---|---|
Type | |
Size | 873.57 KB |
Downloads |
Text Preview
s Series Notification Appliances Chimes and Chime Strobes Indoor Strobe Strobe current draw with temperature compensation to reduce power consumption and wiring costs Overview Wall mount models are available with field selectable Candela settings of 15 30 75 110cd models are available with field selectable candela settings of 15 30 75 95cd or 115 177cd produce one 1 flash per second over the regulated input voltage range can be synchronized using the Siemens DSC sync modules FS 250 panel XLS panel PAD 3 power supply with built in sync protocol volume and tone control stroke or vibrating operation Installation with In Out screw terminals using 12 to 18 AWG wires Listed ULC Listed CSFM NYMEA Approved Meets OSHA 29 Part 1910.165 compliant appliances shall be Siemens Series CH Chimes and the chime strobe appliances shall be Series CH Chime Strobes or approved equals chime shall be UL Listed under Standard 464 for Audible Signal Appliances and chimes equipped strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing Impaired shall incorporate low temperature compensation to ensure the lowest possible current chimes shall use solid state components and shall provide field selectable single stroke or operation with volume and tone control models shall have a peak sound output of 83 dBA Anechoic at 10 feet and an adjustable range of 800 to 1200 Hz inputs shall employ terminals that accept 12 to 18 AWG wire sizes portion of the appliance shall produce a flash rate of one 1 flash per second over the Input Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens shall be of low current design and where multi Candela Chime Strobes are specified the intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15 30 75 110cd for wall mount 15 30 75 95cd or 115 177cd for ceiling mount Series Notification Appliances 2572 Industry Inc Technologies Division continued selector switch for selecting the candela shall be tamper resistant and not accessible from the of the appliance is possible when using the Siemens DSC sync modules FS 250 panel XLS panel PAD 3 power supply with built in sync protocol strobes shall not drift out of synchronization at any time during operation If the sync or Power Supply fails to operate i e contacts remain closed the strobe shall revert to a flash rate chime and the chime strobe appliances shall be designed for indoor surface or flush mounting chime and chime strobe shall incorporate a chime mounting plate with a grille cover which is with two screws for a level finish and shall mount to standard electrical hardware no additional trim plate or adapter notification appliances shall be listed for Applications Notes are designed to flash at one 1 flash per second minimum over their Input Voltage Note NFPA 72 specifies a flash rate of 1 to 2 flashes per second while ADA Guidelines specify flash rate of 1 to 3 flashes per second candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Diagram In Inches Options Industry Inc Technologies Division Data Available in red and white Note These notification appliances are UL Listed as Application and are intended to be used only with Siemens notification appliance circuits The chime must be set at maximum volume for Private Mode Fire Protective Service per UL 464 listing requirements The chime produces a brief inrush current of 0.100 Amps with filtered DC input 0.140 Amps with full wave rectified input with a duration of 100 milliseconds Available in red and white The strobe will produce 1 flash per second over the Input Voltage range The strobes meet the required light distribution patterns defined in UL 1971 The chime must be set at maximum volume for Private Mode Fire Protective Service per UL 464 listing requirements The chime produces a brief inrush current of 0.100 Amps with filtered DC input 0.140 Amps with full wave rectified input with a duration of 100 milliseconds CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT Details for Ordering Including Mounting Options Agency Approvals Approvals ULC FM CSFM Chime Multi Candela Red Chime Multi Candela White CH MC R CH MC W CH MC CR 500 636021 Chime Multi Candela Ceiling Red CH MC CW 500 636022 Chime Multi Candela Ceiling White CH HMC CW 500 636023 Chime Hi Multi Candela Ceiling White CH R CH W CH CW Refer to catalog sheet 2585 for detailed mounting options X X X X Chime Red Chime White Chime Ceiling White listed approved This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2009 sheet dated 7 07 1