Siemens CPY-375, CPY-560 Cylinder Valve Assemblies - 2-1 2 inch Discharge Port, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Sheet Safety Products Engineered Fire Suppression Systems Valve Assemblies 2 1 2 6.4 cm Discharge Port Cylinder Mounting Straps Brackets Top Plug Adapter Liquid Level Indicator Low Pressure Switch CPY 375 CPY 560 AND ENGINEER SPECIFICATIONS For use with Sinorix 227 and Sinorix 1230 High flow rate valve 2 1 2 inch discharge port valve assembly Manual electric or pressure operated Low pressure monitoring switch Wall mounting brackets included Liquid level indicator UL 2166 Listed ULC Listed FM Approved Overview CPY 375 CPY 560 are filled as shown Fill at LB FT3 Lbs Lbs Fill at LB FT3 Lbs Lbs Lbs Lbs CPY 375 and CPY 560 can be filled HFC 227ea suppression agent or with Novec 1230 Fire Protection Fluid CPY 375 and CPY 560 are pressurized nitrogen to 360 psig at 70 21.1 and manufactured tested and marked with D O T or 4BW500 for the various sizes cylinder and valve assemblies are furnished an internal siphon tube Cylinders must mounted in the vertical position size 375 and 560 lbs cylinders use a 6.4 cm outlet These valves pressure seated and designed for time specified in NFPA 2001 meet valve assemblies have Brass body Brass piston with resilient seat Safety disc assembly Pressure gauge Pressure releasing pilot check assembly for and pressure actuation which relieves pressure above the piston and permits piston to travel upward Optional electronic solenoid on the valve relieves the pressure above the piston permits the piston to travel upward Valve Assemblies 2 1 2 Discharge Port Sinorix 6622 Industry Inc Technologies Division Actuator Manual Control Combination Ft Ft Qty of Piston Lbs Lbs Control Head may be installed using the electronic top plug adapter for Ordering Lbs Lbs Lbs Lbs of empty cylinders and Valve Assembly Controls valve sizes accept the same set of valve described below Solenoid Valve Electronic Solenoid Valve is normally closed and opens upon electric energy being thus relieving pressure above the valve and causing the cylinder valve to open electrical connections the Electronic Solenoid is furnished with 24 61 cm pigtails 500 697990BG Electronic Supervised Solenoid Manual Control Head Local Manual Control Head can be installed on top plug adapter When the safety pull pin is out and the actuating lever is moved down causes a pin to depress and open the pilot check the valve Agent pressure is then released the valve piston Actuator Pressure Actuator can be installed on the adapter The Pressure Actuator contains piston to provide the necessary force to open pilot check once pressure from the agent of a primary cylinder applied 1 4 0.64 cm tubing The Pressure is used on pressure operated secondary which are released simultaneously the primary Sinorix cylinder 1 primary cylinder can be used to pressure up to a maximum of seven 7 secondary If more than seven 7 cylinders are the engineer may use two 2 electric Sinorix cylinders cylinder valves have a pressure actuation port The pressure actuation outlet port into the same space as the valve outlet and only under pressure while the valve The port has a 1 8 0.32 cm pipe which is fitted with a pipe plug The pipe is removed when the port is used tubing or pipe is connected to the outlet M run to the pressure actuators on the cylinders Industry Inc Technologies Division Mounting Straps Brackets steel straps and brackets are used to mount cylinders in the vertical position Indicator Liquid Level Indicator operates magnetically there is no need to move or disconnect Uninterrupted hazard protection is a feature brackets which are used for wall mounting are secured to adjacent wall studs brackets and straps are UL Listed ULC as well as FM Approved Liquid Level and is UL Listed ULC Listed well as FM Approved must be factory Liquid Level Indicator 2 Cylinder Maintenance Switch Sinorix Low Pressure Indicating Switch CPY PSS1 is a single pole single switch that is mounted to the cylinder during production CPY PSS1 will remain in the NC when no pressure is set against the In Normal operating position the switch is be set at 360 psig the cylinder valve pressurized CPY PSS1 will move into the open Industry Inc Technologies Division loss of pressure from the cylinder due to discharge or leakage Model moves to a closed position at Model CPY PSS1 is monitored by a point on the fire alarm control FACP The FACP will provide a alarm upon loss of pressure the PSIG set point This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www usa Siemens com Fire Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA in U S A 2016 sheet dated 8 15 7

Related Files