Siemens CPY-LMC2 Local Manual Control Head, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-cpy-lmc2-local-manual-control-head-data-sheet-0738514269.pdf |
---|---|
Type | |
Size | 685.97 KB |
Downloads |
Text Preview
Sheet Safety Products Engineered Fire Suppression Systems Manual Control Head CPY LMC2 AND ENGINEER SPECIFICATIONS Optional emergency release button Equipped with safety pull pin to prevent discharge of Sinorix clean agent Stainless steel operation lock pin Solid brass construction Self venting Overview to the latching solenoid Model CPY LMC2 from is the optional emergency release button that depresses the cylinder valve in order to the clean agent used in Sinorix Engineered Suppression systems CPY LMC2 mounts directly on top of an Electric with Supervision Model CPYEC 2 24 which turn mounts directly on top of the Sinorix cylinder using Model CPY LMC2 the Siemens Pressure Switch Model CPY POS must also be installed order for the fire alarm control panel FACP to receive of manual activation order for the system to be properly reset the solenoid be manually returned to the latched position Model CPY LMC2 Local Manual Control assembly in Sinorix engineered fire suppression systems a local push pin that depresses a Schraeder Valve in the top plug adapter thereby venting the at the top of the piston in the cylinder valve allows the piston to slide upward and begin Sinorix discharge from the cylinder cid 127 continued accordance with NFPA 2001 requirements the Electronic Releasing Solenoid Model CPYEC contains an embedded normally closed N C dry switch that provides supervision to the properly solenoid positioned at the top of the valve orange and yellow wires are the switch contact The black and white wires are the 24 VDC leads Model CPYEC 2 24 solenoid is either electronically or manually actuated by the Local Manual Head Operating the valve vents the pressure the top of the piston in the cylinder valve allowing piston to slide upward and thus activate agent the solenoid is actuated the pin latches cid 127 via the that is in the actuated position To reset the assembly must be removed and the pin pushed inward of Model CPY LMC2 requires the purchase of Supervised Electronic Releasing Solenoid Model install first make sure the CPY LMC2 is in the handle up with the safety pull pin and seal intact Next remove the protection cap from the adapter assembly Finally screw Model CPY to supervised electronic releasing solenoid Model Manual Control Head Sinorix 6630 Industry Inc Technologies Division Diagram for Ordering 500 697925BG 2 Manual Control Head This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www USA Siemens com Fire Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA in U S A 2014 sheet dated 6 11 5