Engineered Fire Suppression Systems Electronic Releasing Solenoid CPYEC 2 24 AND ENGINEER SPECIFICATIONS Sheet Safety Products 24 Volts DC Easily field serviceable replaceable UL Listed ULC Listed Approved Overview solenoids are specially designed for the release of Sinorix agent from Siemens Fire fire suppression systems The solenoid valve is closed NC and will open when electrically This action relieves the pressure above the piston thus causing the cylinder valve to open unit has been tested by Underwriters Laboratories to Standards 1058 and 2166 as well as and Factory Mutual for Sinorix Engineered Fire Suppression Systems Releasing Solenoid CPYEC 2 24 is the 24VDC supervised electronic solenoid used with Sinorix Engineered Fire Systems Specifically CPYEC 2 24 functions by a pin that sits in a latched position without obtaining power and will only open upon receiving a signal the control panel released the latching solenoid opens the cylinder valve extinguishing medium is discharged into the system CPYEC 2 24 which is sold separately fits on tanks with top plug diameter of 1.25 inches 3.2 cm A faster time allows the Sinorix system to quickly the fire hazard latching solenoid is available with an optional emergency button Model CPY LMC2 to manually depress the valve if needed the far right image shown at the top of this page to installing the pin must be reset to avoid accidental In the event of actuation of the solenoid the pin be manually reset before attaching the top plug adapter the cylinder tank Releasing Solenoid Supervised Electronic Releasing Solenoid Model contains an embedded normally closed dry contact switch which is used to supervise the mounted solenoid position on top of the valve accordance with NFPA 2001 requirements orange and yellow wires are the switch contact The black and white wires are the 24 VDC leads Model CPYEC 2 24 solenoid is either operated or actuated by the Local Manual Control Head the valve vents the pressure from the top of piston in the cylinder valve allowing the piston to upward and thus activate agent discharge Once solenoid is actuated the pin latches via the spring is in the actuated position To reset the solenoid must be removed and the pin physically inward solenoid is furnished with 36 91.4 cm pigtails Ratings Coils Duty Class VDC 1 Consumption VDC 0.5 Amps for Ordering 500 697990BG Supervised Solenoid 24 VDC 0.5A 500 697991BG Supervised Solenoid Reset Tool Industry Inc 6624 Infrastructure Building Products Solenoids Sinorix Industry Inc Infrastructure Building Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www USA Siemens com Fire Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA 2021 7