Siemens CRC-6 (for FireFinder) Controllable Relay Card, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-crc-6-for-firefinder-controllable-relay-card-data-sheet-8456792013.pdf |
---|---|
Type | |
Size | 809.88 KB |
Downloads |
Text Preview
s XLS Relay Card CRC 6 Six Independent SPDT Contacts Form 4 Amps 30 VDC 120VAC Resistive 3.5 Amps 120 VAC Inductive 0.6 P F Fully programmable Time based operation Manual or automatic control Supervised coils Built in status and troubleshooting LEDs On board microprocessor UL 864 9th Edition Listed ULC Listed FM CSFM NYMEA Approved Overview Controllable Relay Card Model CRC 6 is used the FireFinder XLS Fire Alarm Control Panel is designed to provide auxiliary control of functions door holder release elevator smoke control lock release etc Model plugs into one 1 slot in the Model CC 5 or CC 2 Card Cage and provides six 6 fully relays relay contains one set of SPDT contacts rated at Amps 30 VDC 120 VAC resistive and 3.5 amps VAC inductive 0.6 PF All relay coils are to ensure proper operation Individual can be automatically activated or through control by event and time logic contained in the Person Machine Model PMI Industry Inc Technologies Division Front View Side View relay may also be either manually controlled or PMI will indicate the affected relay and System Disable indicator will illumi until the relay is returned to an Model CRC 6 has on board LEDs for status and troubleshooting of power communication internal and 24V power source are provided as as indication of each relay operation and for Model CRC 6 is performed using the XLS software configuration tool ZEUS XLS 6314 Ratings and Indicators switch LED FAIL LED FAIL LED FAIL LED ACTIVE LEDs the CRC 6 card system power is to the CRC 6 when the card has failed when the HNET fails and the is in the DEGRADE when the 24 VDC falls below 18 VDC steadily to indicate relay is active and to indicate relay coil There is one LED for of the six relays for Ordering and Humidity Range are UL 864 9th Edition listed for dry locations within a temperature of 120 3 49 2 to 32 3 and at a relative humidity of 93 2 a temperature of 90 3 32 2 This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2010 sheet dated 7 09 2