Siemens D2300CPS Multi Mode (850nm) Fiber Optic Interface, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Installation Instructions D2300CPS Mode 850nm Fiber Optic Interface Model D2300CPS from Siemens Industry Inc See 1 is a Fiber Optic interface for the MXL RS 485 MNET or XNET FireFinder XLS Desigo Fire Modular Cerberus PRO Modular network or XNET or HUB 4 FSI It uses a two fiber pair between each device The D2300CPS can as either a repeater or an end point unit NOT USE 4 NOT USE 3 DATA 2 DATA 1 VDC This module is NOT backwards with the original 5V D2300CP This uses 24VDC Make sure to read the front of module and connect to the correct voltage serious damage to the unit will result 1 Module D2300CPS can operate in either a daisy chain Figure 2 or star configuration See Figure 3 allows for network configurations that are not with the RS 485 network alone D2300CPS module is not listed for use by Mutual Applications requiring fiber con of voice modules systems are therefore Factory Mutual listed not use the D2300CPS with CXL Systems D2300CPS has four keyhole slots for 6 screws the device in the locations listed below using four 6 screws provided bracket P N 500 692880 is available for mounting D2300CPS in any MXL enclosure that will accept MOM 4 See Figure 4 This bracket has the same as the MOM 4 and accommodates two modules An assembly kit is included with bracket that contains four nuts and eight screws the bracket in the enclosure with the four nuts the positions labeled X See Figure 4 Start four of 6 32 screws and slip the keyhole slots in the over them Tighten the four screws 3 style rails that mount on an MBR 2 or MME 3 P N MSR 1 are also available and can be for mounting the D2300CPS with the System 3 Bracket Up to three brackets can be installed on single rail bracket Model D2300 MP is available for mounting D2300CPS modules in any FireFinder XLS Fire Safety Modular Cerberus PRO Modular enclosure The D2300 MP fits in the same as a CC 5 and mounts to the CAB MP A kit is provided for attaching the D2300 MP to CAB MP and mounting two D2300CPS modules the D2300 MP Mount the D2300CPS modules to installing the D2300 MP onto the CAB MP that when using two D2300CPS modules the two mounting holes on each D2300CPS share two center studs on the D2300 MP See Figure 5 CONNECTIONS INPUT D2300CPS uses filtered or unfiltered 24 VDC D2300CPS can only be powered from the listed in Table 1 on page 6 Industry Inc Technologies Division Park NJ 315 050018 6 Canada Ltd North Service Road East Ontario 0H6 Canada MODE DUPLEX OPTICAL FIBER BUDGET MAX LOSS MODE DUPLEX OPTICAL FIBER BUDGET MAX LOSS dB 62.5 125 FIBER dB 50 125 FIBER dB 62.5 125 FIBER dB 50 125 FIBER OHMS 1 4W 140 820150 OHMS 1 4W 140 820150 OHMS 1 4W 140 820150 NODES MAX OHMS 1 4W 140 820150 NODES MAX THE 120 W 5 RESISTOR ASSEMBLY APPLICABLE 140 820150 MMB 1 2 P N 140 049099 MMB 3 NODES MAX OHMS 1 4W 140 820150 Chain Configuration MNET Shown 2 MODE DUPLEX OPTICAL FIBER BUDGET MAX LOSS dB 62.5 125 FIBER dB 50 125 FIBER ADDITIONAL NODES MAX THE 120 W 5 RESISTOR ASSEMBLY APPLICABLE 140 820150 MMB 1 2 P N 140 049099 MMB 3 OHMS 1 4W 140 820150 3 Configuration MNET Shown 500 692880 POWER TO PROTECTION the D2300CPS in an MBR 2 or MME 3 Backbox 4 OPTIC CABLE LIMITED HNET XNET AS SHOWN FAIL FAIL FAULT STATUS A OPEN A RETURN A OPEN A RETURN NETWORKS FAIL FAIL FAIL FAIL FAULT A FAIL B FAIL STYLE 7 4 FAULT FAIL FAIL FAIL FAULT 12A FAIL 4A FAIL the D2300CPS in a CAB 1 Backbox 5 POINT NETWORK FIGURES 7 8 9 POINT BUDGET MAX LOSS dB 62.5 125 FIBER 6 dB 50 125 FIBER BUDGET MAX LOSS dB 62.5 125 FIBER 6 dB 50 125 FIBER the D2300CPS as both a Repeater and End Point Unit 6 RATINGS P P MAX OHMS M

Related Files